期刊文献+

320排CT血管成像在肝癌诊断中的临床应用 被引量:7

Clinical value of 320 - slice CT angiography in hepatocellular carcinoma diagnosis
下载PDF
导出
摘要 目的:评价320排CT三维血管成像(CTA)对原发性肝癌(PLC)的诊断价值。方法:103例介入治疗前行全肝320排CT三期扫描及CTA重建的PLC患者,以DSA为参照,分析CTA对肝内瘤灶、动静脉瘘(AVF)诊断的敏感性、特异性和准确性。并对其中31例合并门静脉癌栓(PVTT)患者比较其CTA与DSA的检出率。结果:CTA和DSA对肝内瘤灶的诊断及其血供评价比较无明显差异(P>0.05);CTA诊断AVF的敏感性和特异性均为100%、准确性为97.1%;31例PVTT患者中CTA发现29例优于DSA的22例(P<0.05)。结论:320排CT及其CTA重建可对介入治疗前的PLC作出快速而准确的诊断与评价,具有较好的应用价值。 Objective:To evaluate the diagnostic value of clinical application of 320-slice CT angiography(CTA) in primary hepatic carcinoma(PLC).Methods:All 103 PLC cases underwent 320-slice CT three-phase scan and the CTA reconstruct before interventional treatment,the sensitivity,specificity and accuracy of CTA for detecting hepatic arteriovenous fistula(AVF) and tumor foci in the liver in research group were analysed,and select the merger of PVTT compared with 31 patients with the positive rate of CTA with DSA.Results:CTA and DSA showed that there were no significant difference in diagnostic accuracy and evaluation of blood supply of tumor.The sensitivity,specificity and accuracy of CTA for AVF were 100%,100% and 97.1%.CTA was superior to DSA for detecting the hepatocellular carcinoma associated with tumor thrombus in portal vein(PVTT) (P < 0.05).Conclusion:320-slice CT and CTA reconstruct can make rapid and accurate diagnosis and evaluation before interventional therapy of PLC.
出处 《现代肿瘤医学》 CAS 2013年第9期2100-2103,共4页 Journal of Modern Oncology
基金 厦门市科技计划基金资助项目(编号:3502Z20114033)
关键词 320排CT 血管成像 肝癌 诊断 320-slice CT angiography primary hepatic carcinoma diagnosis
  • 相关文献

参考文献9

二级参考文献58

  • 1杨广君.原发性肝癌的螺旋双期增强扫描影像特征分析(附42例病例报告)[J].中外健康文摘:临床医师,2008,0(6):203-203. 被引量:1
  • 2王怡宁,金征宇,孔令燕,宋兰,张竹花,张抒扬,林松柏,牟文斌,王沄,赵文敏,郭家武.64层螺旋CT冠状动脉成像初步研究[J].中华放射学杂志,2006,40(8):797-801. 被引量:99
  • 3强永刚,张秀萍,廖永华,李健,黄正.论“放射防护学”课程在医学教育中的地位与作用[J].中国高等医学教育,2007(3):74-76. 被引量:26
  • 4Dewey M. Noninvasive Coronary A ngiography by 320-Row Computed Tomography with Lower Radiation Exposure and Maintained Diagnostic Accuracy[J]. Circulation,2009,120: 867-875. 被引量:1
  • 5J Geleijns. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting:Technical note[J]. Phys. Med. Biol,2009, 54: 3 141-3 159. 被引量:1
  • 6John Hoe,MBBS,DMRD,et al. First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose [J]. Journal of Cardiovascular Computed Tomography, 2009 (5):257-261. 被引量:1
  • 7Steigner ML,Otero HJ,Cai T,et al. Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography[J]. The International Journal of Cardiovascular Imaging (formerly Cardiac Imaging) ,2009,25 ( 1 ):85- 90. 被引量:1
  • 8Marc Dewey, Elke Zimmermann, Michael Laule,et al.Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography[J], AJR ,2009,193 : 1 514-1 521. 被引量:1
  • 9Sundeep S. Pasricha,Dee Nandurkar,Sujith K. Seneviratne, et al. Image Quality of Coronary 320-MDCT in Patients With Atrial Fibrillation[J]. Initial Experience ,2009,193 : 1 514-1 521. 被引量:1
  • 10Sonja Kandel,Christian Kloeters,Henning Meyer,et al.Wholeorgan perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma:acquisition technique, post-processing and initial results[J]. European Radiology,2009, 19(11): 2 641-2 646. 被引量:1

共引文献81

同被引文献58

引证文献7

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部