摘要 介绍了在钨酸铅晶体发光特性研究中温度效应的影响、钨酸铅晶体从 1 2~ 36℃变化时测量温度系数的方法 。 A water cooling system is built to measure temperature coefficient in the study of PbWO 4 crystals to get the precise light yield of the crystal. PWO temperature coefficient is measured from 12~36℃. The stability after the installation of a crystal is also studied.
作者 汪晓莲 许彤
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2000年第6期401-403,共3页 Nuclear Electronics & Detection Technology
基金 中科院国际合作局重大项目 国家自然科学基金支持项目! ( 59932 0 0 2 )
关键词 钨酸铅 光产额 温度效应 电磁量能器 探测器 PbWO4 crystals light yield temperature coefficient
  • 相关文献

参考文献4

  • 1[1] CMS Collaboration, Compact Muon Solenoid Technical Proposal[R], CERN/LNCC 94-38 被引量:1
  • 2[2] CMS Collaboration, The Electromagnetic Calorimeter Project[R], Technical Design Report, CERN/LHCC97-33 被引量:1
  • 3[3] Baccaro S,et al. Precise determintion of the light yield of scintillating crystals[J].Nucl Instrum Methods,.1997, A 325: 69. 被引量:1
  • 4[4] Lecoq P, et al. Lead tungstate (PbWO4) scintillators for LHC EM-calorimetry[J]. Nucl. Instrum Methods,1995, A 365:291. 被引量:1