期刊文献+

双回路EPR法测定奥氏体不锈钢的敏化 被引量:23

EXAMINATION OF SENSITIZATION OF AUSTENITIC STAINLESS STEELS BY DOUBLE-LOOP EPR TEST METHOD
下载PDF
导出
摘要 采用双回路电化学动电位再活化 (EPR)方法对经固溶处理和热处理后的奥氏体不锈钢进行了敏化测试 ,得到C型TTS图 ,并与根据化学测试方法建立的相应图对比 ,发现用双回路EPR方法测定奥氏体不锈钢的敏化更灵敏和准确 . Sensitization of austenitic stainless steels, which were traditionally examined by solution and heat treatments, are measured by double\|loop EPR test method . The C type TTS curves of various samples are obtained , and then compared with the curves established by the Rocha and Cihal. The results indicate that the EPR technique can detect low degrees of sensitization and can be performed quickly. The areas of sensitization determined by the prosend method are larger than that by Rocha and Cihal′s curves.
作者 李神速
出处 《腐蚀科学与防护技术》 CAS CSCD 2000年第5期288-291,共4页 Corrosion Science and Protection Technology
关键词 奥氏体不锈钢 敏化 双回路EPR方法 测定 austenitic stainless steels, sensitization, double\|loop EPR
  • 相关文献

参考文献3

  • 1Wachter V O,VGB Kraftwerkstechnik,1996年,76卷,6期,514页 被引量:1
  • 2Kilian R,Symposium on Environmental Degradation of Materials in Nuclear Power Systems Wat,1995年,1期,529页 被引量:1
  • 3Rocha H J,DEW Technische Berichte,1962年,2卷,1期,16页 被引量:1