一种具有衬底温度补偿功能的非制冷红外读出电路 被引量:2

An uncooled infrared readout circuit with substrate temperature compensation
下载PDF
导出
摘要 针对非制冷红外探测器系统,设计了一种无需衬底温度稳定器——热电制冷器(TEC)的读出电路(ROIC)结构.首先分析了衬底温度对微测辐射热计的特性的影响,利用ROIC对衬底温度变化引起的微测辐射热计的特性的变化进行补偿,实现ROIC的输出信号与衬底无关.该ROIC已在0.5μm CMOS工艺下成功流片,并应用了到阵列大小为320×240的非制冷微测辐射热计焦平面上.测试结果表明:在衬底温度变化20 K时,ROIC输出信号仅变化2 mV,实现了去除TEC后衬底温度补偿的功能,有效地降低了系统功耗.该ROIC在低功耗,小体积的非制冷红外探测器上有着广泛的应用. A new read-out IC (ROIC) architecture with substrate temperature compensation was introduced for the un- cooled microbolometer detector. The influence of responsivity on the substrate temperature was evaluated. Numerical simulation and measurement of the proposed ROIC architecture demonstrated high quality of signal over wide temperature range without using multiple corrections. A 320 x 240 uncooled microbolometer focal plane array(FPA) based on the proposed circuit was implemented on silicon using a 0.5 Ixm CMOS technology. The measurement data show that the maximum difference of the output voltages is only 2mV over the change of 20K in the substrate temperature. This archi- tecture is expected to allow removal of the thermoelectric cooler (TEC) from uncooled systems. Thus it is ideally suited for low-cost, low-power, and low-weight production applications.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2013年第3期248-253,共6页 Journal of Infrared and Millimeter Waves
基金 国家自然科学基金(61235006)~~
关键词 非制冷 微测辐射热计 热电制冷器(TEC) 读出电路(ROIC) uncooled microbolometer TEC ROIC
  • 相关文献

参考文献6

  • 1Lv Jian, Jiang Ya-Dong, Zhang Dong-Lu, et al. An ultra low noise readout integrated circuit for uncooled microbo- lometer[ J]. Analog lntegr Circ Sig Process, 2010,66(3) : 489 - 494. 被引量:1
  • 2Parish W J, Woolaway J T. Improvements in uncooled sys- tems using bias equalizationIJ]. Proc. SPIE, 1999,3698: 748 - 755. 被引量:1
  • 3Parish W J, Woolaway J T. Low Cost 160 × 128 uncooled infrared sensor array[J]. Proc. SPIE, 1998 ,3360: 111- 119. 被引量:1
  • 4Fraenkel A, Mizrahi U, Bykov L, et al. Advanced features of SCD' s uncooled detectors [ J ]. Opto-Electronics Review, 2006,14( 1 ) :47 - 54. 被引量:1
  • 5Michael A. Demanenko. Improved bias equalization meth-od for suppression temperature-induced errors in microbo- lometer FPA over 20 K substrate temperature change [ J ], Proc. SHE, 2007, 6542: 654222_1-654222_9. 被引量:1
  • 6Parish W J. Microbolometer focal plane array methods and circuitry Methods and circuitry [ P ], United States Patent, 2004, NO. 6812465B2. 被引量:1

同被引文献291

引证文献2

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部