摘要
本文从最基本的单相接地故障分析所使的用的复合序网入手,分析了不同中性点接地方式下发生单相接地故障时复合序网的构成,将复合序网法应用于小电流接地系统的单相接地故障的分析,统一了在不同中性点接地方式下的复合序网分析方法。这种方法可使学生易于理解和记忆。,并能引导他们利用已学过的知识进行分析并延拓思路。
Based on the analysis of the formulation of composite sequence networks under different neutral grounding system when single-phase ground fault occurs,this paper applies the composite sequence network method in the analysis of single phase ground fault in the small current grounding system.The unified single phase fault analysis method under different neutral grounding system enable students to utilize the composite sequence network method much easier and extend their knowledges.
出处
《电气电子教学学报》
2013年第2期82-84,93,共4页
Journal of Electrical and Electronic Education