期刊文献+

PMMA强化骨质疏松条件下椎弓根螺钉稳定性的研究进展 被引量:1

Research progress of augmentation of pedicle screw stability with polymethylmethacrylate in patients with osteoporosis
下载PDF
导出
摘要 随着我国人口老龄化的日益加剧,如何有效的提高骨质疏松条件下椎弓根螺钉的稳定性、防止螺钉松动已经成为脊柱外科亟待解决的难题。目前凭借出色的机械强度,PMMA已经被广泛的应用于强化骨质疏松条件下椎弓根螺钉的稳定性。然而在众多的研究中,PMMA的注射剂量、注射方法及椎弓根螺钉的设计差异很大。本文就目前PMMA强化骨质疏松条件下椎弓根螺钉稳定性的研究进展做一综述。 With the aging of the population aggravating in our country, how to effectively increase the stability of pedicle screw in patients with osteoporosis (OP) and to prevent loosening of the screw has become an urgent problem in spine surgery. Based on the effective mechanical strength, Polymethylmethacrylate (PMMA) has been widely used in the augmentation of pedicle screw stability in patients with OP. However, the injection methods of PMMA, injected volume of PMMA, and the design of pedicle screw in various researches are different. This paper reviews research progress of augmentation of pediele screw stability with PMMA in patients with OP.
出处 《中国骨质疏松杂志》 CAS CSCD 北大核心 2013年第5期525-528,共4页 Chinese Journal of Osteoporosis
关键词 椎弓根螺钉 骨质疏松 稳定性 聚甲基丙烯酸甲酯 综述 Pedicle screw Osteoporosis Stability Polymethylmethacrylate Review
  • 相关文献

参考文献5

二级参考文献54

共引文献45

同被引文献45

  • 1王瑞,靳安民,童斌辉,宋富立,张辉,姚伟涛.胸腰椎短节段椎弓根螺钉内固定翻修的原因和预防[J].骨与关节损伤杂志,2004,19(11):721-723. 被引量:36
  • 2黎逢峰,张庆宏,黄野,王云华.磷酸钙骨水泥强化椎弓根螺钉固定的生物力学特性(英文)[J].中国临床康复,2006,10(25):187-190. 被引量:3
  • 3张海兵,金大地,瞿东滨.骨水泥在骨质疏松椎体中强化和翻修椎弓根螺钉的生物力学研究[J].中国临床解剖学杂志,2007,25(5):587-589. 被引量:8
  • 4Moon B J, Cho BY, Choi EY, et al. Polymethylmethacrylate- augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37 patients. J Korean Neurosurg Soc. 2009;46(4):305-311. 被引量:1
  • 5Wu ZX, Gao MX, Sang HX, et al. Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients. J Surg Res. 2012;173(1):91-98. 被引量:1
  • 6刘达,潘显明,廖冬发,等.不同剂量聚甲基丙烯酸甲酯骨水泥强化骨质疏松人工骨模块中椎弓根螺钉稳定性的研究[J].中华临床医师杂志(屯子版),2013(14):6477-6480. 被引量:1
  • 7Wichmann JL, Booz C, Wesarg S, et al. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength. Eur Radiol. 2015;25(6): 1714-1720. 被引量:1
  • 8Gerard CS, Fessler RG. Accurate pedicle screw placement--a perspective statement. World Neurosurg. 2015;83(5): 747-749. 被引量:1
  • 9Padanyi Csaba, Misik F, Papp Z, et al. Treatment of osteoporotic vertebral compression fractures with PMMA-augmented pedicle screw fixation, ideggyogy Sz. 2015;68(1-2):52-58. 被引量:1
  • 10Pfeiffer FM, Choma T J, Kueny R. Finite element analysis of Stryker Xia pedicle screw in artificial bone samples with and without supplemental cement augmentation. Comput Methods Biomech Biomed Engin. 2015; 18(13): 1459-1467. 被引量:1

引证文献1