摘要
为了探寻高效的冷却技术,将多斜孔壁冷却结构应用于燃烧室火焰筒中,在实际工作条件下,对三种孔排布方式的火焰筒冷却特性进行了数值模拟。研究了斜排孔阵的周向偏移量H相对周向孔间距p的变化(模型A:H/p=0.2;模型B:H/p=0.4;模型C:H/p=0.5)对冷却特性的影响。计算结果表明,在燃烧室进口条件相同时,H/p的变化对总冷却用气量的影响很小,但对火焰筒的传热特性有明显影响,模型C的冷却效果优于模型A和B,并且火焰筒出口的温度分布不均匀系数ε较小。
To investigate effective cooling method,effusion-cooling was applied in combustion chamber flame tube.The heat transfer characteristics of three effusion cooling structures under actual conditions were studied.The effects of different circumferential array displacement H to circumferential spacing p of holes array(model A:H/p=0.2;model B:H/p=0.4;model C:H/p=0.5)on the cooling characteristics were investigated.The computation results show H/p has little effect on the total flow rate of cooling air but an obvious effect on heat transfer characteristics.The cooling effectiveness of model C is higher than that of model A and B and the outlet temperature distribution factor ε on the outlet of flame tube is the smallest.
出处
《推进技术》
EI
CAS
CSCD
北大核心
2013年第5期638-643,共6页
Journal of Propulsion Technology
关键词
多斜孔壁冷却
孔排布
火焰筒
燃烧室
Effusion cooling
Hole displacement
Flame tube
Combustion chamber