期刊文献+

预臭氧化工艺处理低温低浊水的应用研究 被引量:5

APPLICATION RESEARCH ON PREOZONATION FOR TREATMENT OF LOW TEMPERATURE AND LOW TURBIDITY WATER
下载PDF
导出
摘要 通过进行预臭氧化-紫外/氯工艺处理低温低浊期水源的生产性试验,分别对各处理单元出水pH、浊度、DOC和UV254进行了测定。结果表明,在低温低浊期,整套工艺对浊度、DOC和UV254的平均去除率分别为93.83%、29.38%和57.20%。此外,预臭氧化单元对pH及去除浊度、DOC和UV254也有一定的影响。预臭氧化单元可有效降低UV254,但对浊度和DOC的去除效果不明显。 A full-scale study was performed on the process of preozonation-UV/chlorine disinfection for treatment of low temperature and low turbidity water, and pH, turbidity, DOC and UV254 values in outflow from the treatment units were determined. The results show that during the low temperature and low turbidity period, the average removal rates of turbidity, DOC and UV254 for the whole process were 93.83%, 29.38% and 57.20%, respectively. In addition, preozonation unit have certain effect on pH, turbidity, DOC and UV254 in raw water. Preozonation unit can effectively reduced UV~ values, but had little effect on the removal rates of turbidity and DOC.
出处 《水处理技术》 CAS CSCD 北大核心 2013年第5期73-75,共3页 Technology of Water Treatment
基金 国家自然科学基金资助项目(51008162) 天津市应用基础及前沿技术研究计划资助项目(10JCYBJC03500)
关键词 预臭氧化 低温低浊 UV254 preozonation low temperature and low turbidity UV254