期刊文献+

携抗P-选择素单抗靶向超声造影剂的制备及体外寻靶实验研究 被引量:3

Preparation and targeting study in vitro of P-selectin antibody loaded targeted ultrasound contrast agent
原文传递
导出
摘要 目的制备携抗P-选择素(P-seleetin)单抗的靶向超声造影剂,并研究其体外寻靶能力。方法采用“亲和素-生物素”桥接法制备携抗P—selectin单抗靶向超声造影剂,检测其基本特性。应用不同剂量重组人白介素4(rhIL-4)和组胺联合刺激人脐静脉血管内皮细胞(HuVEcs)表达P—selectin,用免疫荧光检测P—selectin的表达水平并探寻rhIL-4最适刺激剂量。靶向超声造影剂、同型对照超声造影剂和空白超声造影剂分别与经最适剂量rhIL-4和组胺联合刺激的HUVECs和未作处理的HUVECs进行体外寻靶实验。结果成功制备携抗P—selectin单抗靶向超声造影剂,平均粒径为(2.24±0.71)弘m,平均Zeta电位为(-2.75±0.84)mV,浓度为(3.0±0.3)×10^9个/ml,抗体结合率高达99.80%;免疫荧光检测结果显示rhIL-4和组胺能成功刺激HUVECs表达P—selectin,并探寻出rhlL一4最适刺激剂量;体外寻靶实验显示靶向超声造影剂能较好地黏附在经最适剂量rhIL-4和组胺联合刺激的HUVECs表面,与其他组比较差异有统计学意义(P〈0.01)。结论采用“亲和素一生物素”桥接法成功制备携抗P—selectin单抗靶向超声造影剂,该造影剂在体外能有效地黏附在经rhIL-4和组胺联合刺激的HUVECs表面。 Objective To prepare a kind of P-selectin antibody loaded-targeted ultrasound contrast agent,and to investigate its ability of targeting in vitro. Methods P-selectin antibody loaded-targeted ultrasound contrast agent was prepared via an "avidin-biotin" bridge. Its basic property was determined. Human umbilical vein endothelial cells (HUVECs) were stimulated to express P-selectin by applying different doses of recombinant human interleukin-4 (rhIL-4) and histamine. The expression level of P-selectin was detected by immunofluorescence technique, and explored rhlL-4 optimal stimulation dose. The experiment group was divided into 3 groups, including targeted ultrasound contrast agent, isotype control ultrasound contrast agent and blank ultrasound contrast agent. Targeting abilities of 3 groups were observed by adhering to treated HUVECs and untreated HUVECs,respectively. Results P-selectin antibody loaded- targeted ultrasound contrast agent was prepared successfully. The average diameter was (2.24± 0.71)μm. The average Zeta potential was ( - 2.75 ± 0.84) inV. The concentration was (3.0 ±0.3) × 10^9/ml. The rate of antibody binding was as high as 99.80%. RhIL-4 and histamine could stimulate HUVECs to express P- selectin,and optimal stimulation dose was obtained. Targeting experiment showed that targeted ultrasound contrast agent could preferably adhere to HUVECs stimulated by optimal dose of rhIL-4 and histamine. Compared with other groups, there were significant differences. Conclusions P-selectin antibody-loaded targeted ultrasound contrast agent was prepared successfully via an "avidin-biotin" bridge. The targeted ultrasound contrast agent could effectively adhere to HUVECs stimulated by rhIL-4 and histamine.
出处 《中华超声影像学杂志》 CSCD 北大核心 2013年第4期349-354,共6页 Chinese Journal of Ultrasonography
基金 国家自然科学基金青年科学基金项目(81000621) 教育部博士点(新教师类)基金项目(20105503120008) 国家自然科学基金重点项目(81130025) 2010年度重庆高校优秀成果转化资助项目(Kjzh10201)
关键词 微气泡 P-选择素 Microbubbles P-selectin
  • 相关文献

参考文献15

  • 1Kaufmann BA, Lewis C, Xie A, et al. Detection of recentmyocardial ischaemia by molecular imaging of P-selectin with targeted contrast echocardiography. Eur Heart J, 2007,28 : 2011- 2017. 被引量:1
  • 2Weller GE, Villanueva FS, Tom EM, et al. Targeted ultrasound contrast agents: in vitro assessment of endothelial dysfunction and multi-targeting to ICAM-1 and sialyl Lewisx. Biotechnol Bioeng, 2005,92 : 780-788. 被引量:1
  • 3王志刚.超声微泡造影剂在疾病诊断与治疗中的研究进展[J].中国医学影像技术,2005,21(8):1148-1150. 被引量:46
  • 4景香香,王志刚.超声造影剂靶向性作用机制的研究进展[J].临床超声医学杂志,2003,5(6):359-360. 被引量:14
  • 5Kaufmann BA, Lewis C, Xie A, et al. Detection of recent myocardial ischaemia by molecular imaging of P-selectin with targeled contrast echocardiography. Eur Heart, 2007,28 : 2011- 2017. 被引量:1
  • 6Villanueva FS, Lu F, Bowry S, et al. Myocardial isehemic memory imaging with molecular echocardiography. Circulation, 2(11}7,115:345-352. 被引量:1
  • 7Dayton PA, Rychak JJ. Molecular ultrasound imaging using microbubble contrast agents. Front Biosci,2007,12 : 5124-5142. 被引量:1
  • 8Inaha Y, Lindner JR. Molecular imaging of disease with targeted contrast ultrasound imaging. Transl Re,s, 2012,159 : 140-148. 被引量:1
  • 9Babich V, Knipe L, Hewlett L, et al. Differential effect of extracellular acidosis on the release and dispersal of soluble andmembrane proteins secreted from the Weibel-Palade body. Biol Chem, 20(19,284 : 12459-1268. 被引量:1
  • 10Burns AR, Bowden RA, Abe Y, et al. P-seleetin mediates neutrophil adhesion to endothelial cell borders. J Leukocyte Biol, 1999,65 ; 299-306. 被引量:1

二级参考文献37

共引文献56

同被引文献31

  • 1Mozaffari MS, Liu JY, Abebe W, et al. Mechanisms of load de- pendeney of myocardial isehemia reperfusion injury. Am J Cardio- vase Dis, 2013,3(4) : 180-196. 被引量:1
  • 2Hausenloy DJ, Yellon DM. Myocardial isehemia-reperfusion injury: A neglected therapeutic target. J Clin Invest, 2013,123(1) :92-100. 被引量:1
  • 3Chukwuemeka AO, Brown KA, Venn GE, et al. Changes in P-selectin expression on cardiac microvessels in blood-perfused rat hearts subjected to ischemia-reperfusion. Ann Thorac Surg, 2005,79(1) :204-211. 被引量:1
  • 4Senior R, Shah BN. Myocardial contrast echocardiography for simultaneous assessment of function and perfusion in real time: A technique comes of age. Circulation, 2012,126(10):1182-1184. 被引量:1
  • 5Trindade ML, Vieira ML, Rodrigues AC, etal. Contrast echo- cardiography in myocardial infarction. Einstein (Sao Paulo), 2013,11(3) :392-397. 被引量:1
  • 6Kaufmann BA, Lewis C, Xie A, et al. Detection of recent myocar- dial ischaemia by molecular imaging of P-selectin with targeted contrast echocardiography. Eur Heart J, 2007,28(16) :2011-2017. 被引量:1
  • 7Leong-Poi H. Molecular imaging using contrast-enhanced ultra- sound: Evaluation of angiogenesis and cell therapy. Cardiovasc Res, 2009,84(2) : 190-200. 被引量:1
  • 8Turkbey B, Kobayashi H, Ogawa M, et al. Imaging of tumor an- giogenesis: Functional or targeted? AJR Am J Roentgenol, 2009, 193(2) :304-313. 被引量:1
  • 9叶露薇,王志刚,冉海涛,等.携抗CD34和抗ICAM-1双抗体的靶向超声对比剂的制备及鉴定[C].中国超声医学工程学会第十一届全国超声医学学术大会论文汇编,2012:278-279. 被引量:1
  • 10Moestue SA, Gribbestad IS, Hansen R. Intravascular targets for molecular contrast-enhanced ultrasound imaging [J]. Int J Mol Sci, 2012, 13 (6) : 6679-6697. DOI : 10. 3390/ijms13066679. 被引量:1

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部