摘要
在分析船舶电站突加负载引起电网电压跌落问题的基础上 ,给出了对船舶电站自动励磁调节装置有关参数的要求 ,并给出具体表达式。
The dynamic performance of marine power stations depends mainly on the dynamic performance of exciting system.In this paper,the voltage dip in marine power station caused by emergency load and some key factors of exciting system are discussed,some concerned expressions are also given.
出处
《中国修船》
北大核心
2000年第5期24-26,共3页
China Shiprepair
关键词
突加负载
励磁装置
电压跌落
船舶电站
emergency load
exciting regulator
voltage dip
synchronous generator