摘要
电缆的充电功率会对电网无功平衡造成一定影响,轻负荷时期其影响尤为明显。以温州电网为算例,分析了轻负荷时期不同运行方式下高压电缆充电功率对电网无功平衡的影响,并提出了改进建议。
Charging power of power cables has impact on reactive balance of power grid, especially during light load periods. By taking Wenzhou power grid as an example, the paper comparatively studies impacts of charging power of high-voltage cables on reactive balance of power grid in different operating modes during light load periods; it also proposes some recommended measures.
出处
《浙江电力》
2013年第2期20-22,30,共4页
Zhejiang Electric Power
关键词
电缆
充电功率
无功平衡
轻负荷
cable
charging power
reactive balance
light load