期刊文献+

长期颈内静脉留置导管的应用及护理 被引量:1

下载PDF
导出
摘要 [目的:通过对110例带Cuf f涤纶环长期颈内静脉留置导管在血液透析中的应用和护理,研究在使用过程中出现的常见并发症并总结相应的护理对策。方法:在无菌局麻下采用Sel di nger技术穿刺颈内静脉留置导管,通过撕脱型外套送入血管。结果:经颈内静脉建立长期血管通路的110例患者中,导管相关感染18例,导管堵塞7例,出血血肿5例,自行拔管2例,导管破裂1例,分别占16.36%、6.36%、4.54%、1.82%、0.91%。结论:长期颈内静脉留置导管是治疗慢性肾衰竭患者的一种及时、迅速、安全、有效的方法,它使用时间长、栓塞率、感染率较低,成功的置管,严格无菌操作,优质的护理能预防并发症的发生,有利于提高血液透析患者的透析质量。
作者 方晶
出处 《中国美容医学》 CAS 2012年第11X期352-352,共1页 Chinese Journal of Aesthetic Medicine
  • 相关文献

参考文献2

二级参考文献31

  • 1[1]Ori Y, Korzets A, Katz M et al. Haemodialysis arteriovenous access-aprospective haemodynamic evaluation. Nephrol Dial Transplant, 1996, 11(Suppl 1):94 被引量:1
  • 2[2]Krivitski NM, MacGibbon D, Gobson A.Accuracy techniques for access flow measurement during hemodialysis. Am J Kidney Dis, 1998,31(3):502 被引量:1
  • 3[3]Sands J, Glidden D, Miranda C. Hemodialysis access flow measurement. Comparison of ultrasound dilution and duplex ultrasonography. ASAIO J, 1996,42(5):899 被引量:1
  • 4[4]Von Bibra H, Castro L. Autentiech G et al. The effects of ateriovenous shunts on cardiac function in renal dialysis patients-an echocardiographic evalution. Clin Nephrol, 1978,9(5):205 被引量:1
  • 5[5]Bos WJ, Zietse R, Wesseling KH et al. Effects of arteriovenous fistulas on cardiac oxygen supply and demand. Kidney Int, 1999,55(5):2049 被引量:1
  • 6[6]Moore GE, Painter PL, Brinker KR et al. Cardiovascular response to submaximal stationary cycling during hemodialysis.Am J Kindey Dis, 1998, 31(4):631 被引量:1
  • 7[7]Dongradi G, Rocha P, Kahn JC et al. Patients on chronic hemodialysis. Hemodynamic study at rest and during execise before dialysis, in hypertensive and normotensive patients (authors transl). Nouv Presse Med, 1978,7(36):3207 被引量:1
  • 8[8]Lo WK, Mo FKF, Po CH et al. Effect of exercise during hemodialysis:result of a 3 month pilot study. Hong Kong J Nephrol, 2000,2(1):27 被引量:1
  • 9[9]Dongradi G, Rocha P, Baron B et al. Hemodynamic effects of arteriovenous fistulae in chronic hemodialysis patients at rest and during exercise. Clin Nephrol, 1981,15(2):75 被引量:1
  • 10[10]Pandeya S, Lindsay RM. The relationship between cardiac output and access flow during hemodialysis. ASAIO J, 1999,45(3):135 被引量:1

共引文献150

同被引文献6

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部