摘要
对造成己内酰胺废液焚烧装置引风机腐蚀、积灰、振动等的原因进行了分析,提出了解决措施和改进设想,提高了装置的运行周期。
The cause of the caprolactam waste incineration plant's induced draft fan's corrosion, ash deposition, vibration was analyzed, the solutions and suggestions were given, and the run ning period of plant was improved.
出处
《石油化工设备》
CAS
2012年第6期89-91,共3页
Petro-Chemical Equipment
关键词
引风机
己内酰胺废液
焚烧
运行
induced draft caprolactam waste incineration operation