期刊文献+

输液温度对老年全麻患者术后恢复的影响 被引量:8

下载PDF
导出
摘要 目的:研究输液温度对老年全麻患者术后恢复的影响。方法:选取60岁以上开腹全麻患者116例,随机分为对照组和观察组,对照组常温下输液,观察组采用加温器控制输液温度约37℃,记录患者围手术期体温下降值、复苏后完全清醒时间、围手术期低体温综合征例数及术后反应性精神障碍例数。结果:对照组较观察组围手术期体温下降辐度大,麻醉复苏后完全清醒时间延长,术后反应性精神障碍例数增多,差异具有统计学意义(P<0.05);两组围手术期低体温综合征例数差异无明显统计学意义(P>0.05)。结论:加温输液能减少围手术期低体温发生率,帮助术后尽早复苏及减少并发症。
出处 《护理实践与研究》 2012年第21期38-39,共2页 Nursing Practice and Research
  • 相关文献

参考文献5

  • 1Kabon B, Bacher A, Spiss CK. Therapeutic hypothermia [ J ]. Best Practice Res clin Anaesthesiol,2003,17(4) :551 -568. 被引量:1
  • 2Mahoney CB, Odom J. Maintaining intmoperative normothermia:A meta- analysis of outcomes with costs[ J]. AANA J, 1999,67 ( 2 ) : 155 - 163. 被引量:1
  • 3Matsuzaki Y, Matsukawa T, Ohki K, et al. Warming by resistive heating maintains perioperative normothermia as well as forced air heating[J]. Br J Anaesth,2003,90(5) :689 -691. 被引量:1
  • 4郑小春,李松莲,吴秀东.不同输液温度对老年患者术中体温影响的研究[J].护理与康复,2006,5(4):243-245. 被引量:22
  • 5Frank SM, Beanie C, Christopherson R, et al. Epidural versus gener- al cathesia ambient operation loom temperature and patient age as of inadvertent hypothemia [ J ]. Anesthesiology, 1992,77 ( 2 ) : 252 - 257. 被引量:1

二级参考文献3

共引文献21

同被引文献74

  • 1徐鹏,刘纯燕.加温输液在围手术期的应用进展[J].国外医学(护理学分册),2005,24(9):487-490. 被引量:48
  • 2徐帆,张艺川.关于静脉输注液体温度偏低引发相关问题的思考[J].护理研究(下旬版),2006,20(5):1384-1384. 被引量:3
  • 3Assuncao R, Barbosa P, Ruge R, et al. DeveIoping the control sys- tem of a syringe infusion pump. //Remote Engineering and Virtual Instrumentation (REV), 2014 11th International Conference on. IEEE, 2014:254-255. 被引量:1
  • 4Amano H, Ogawa H, Maki H, et al. A remote drip infusion monito- ring system employing Bluetooth. Engineering in Medicine and Biolo- gy Society (EMBC), 2012 Annual International Conference of the IEEE. IEEE, 2012: 2029-2032. 被引量:1
  • 5Jianwen C, Han Z. Design of intravenous infusion monitoring and alarm system based on wireless communication technology. Mecha- tronics and Automation (ICMA), 2011 International Conference on, IEEE, 2011 : 130-134. 被引量:1
  • 6Sosna C, Buchner R, Lang W. A temperature compensation circuit for thermal flow sensors operated in constant-temperature-difference mode. Instrumentation and Measurement, IEEE Transactions on, 2010; 59(6) : 1715-1721. 被引量:1
  • 7Sessler DI. Perioperative heat balance[M]. Anesthesiology, 2000 :578-596. 被引量:1
  • 8Hasegawa K1, Negishi C, Nakagawa F,et al. Core tempera-tures during major abdominal surgery in patients warmed withnew circulating-water garment, forced-air warming,or carbon-fiber resistive-heating system[J]. J Anesth, 2012,26 (2) : 168-173. 被引量:1
  • 9Mitchell AMI,Kennedy RR. Preoperative core temperatures inelective surgical patients show an unexpected skewed distribu-tion[J]. Can J Anaesth,2001,48(9) :850-853. 被引量:1
  • 10Lenhardt R. The effect of anesthesia on body temperature con-trol[M]. Front Biosci(Schol Ed) ,2010:1145-1154. 被引量:1

引证文献8

二级引证文献72