AP1000外部灾害情形下乏燃料池缓解策略研究 被引量:7

Study on Mitigation Strategy of AP1000 Spent Fuel Pool Exterior Disaster
下载PDF
导出
摘要 日本福岛核事故后,乏燃料池(SFP)在事故中的安全性得到广泛的关注。AP1000乏燃料池冷却系统(SFS)是一非安全相关的系统,不需在事故后运行以缓解设计基准事故。但乏燃料池在超设计基准事故或外部灾害事件(包括自然灾害和人为事件)下的安全性一直是核电厂设计的重点。本工作结合美国核能研究所(NEI)给出的扩大损害的缓解导则(EDMG)提出了针对AP1000外部灾害情形下的SFP缓解策略(包括内部策略和外部策略),并对策略进行了评估。本工作结论有助于AP1000SFP EDMG的建立,对AP1000核电厂的设计、建造、运行管理和事故管理均有很强的参考价值。 After Fukushima nuclear accident,much attention has been paid to the safety of the spent fuel pool(SFP).AP1000 spent fuel pool cooling system(SPS) is not a safety related system.It is not designed for design basis accident.But the safety of SFP in exterior disaster and severe accident is very important.The extensive damage mitigation guidelines(EDMG) of NEI to AP1000 SFP accident mitigation was studied,including internal strategy and external strategy.The results are useful for design AP1000 nuclear power plant and the mitigation when SFP exterior disaster happens.
作者 徐红
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2012年第B09期473-478,共6页 Atomic Energy Science and Technology
关键词 AP1000 乏燃料池 核电厂外部灾害 扩大损害的缓解导则 AP1000 spent fuel pool exterior disaster of nuclear power plant extensive damage mitigation guidelines
  • 相关文献

参考文献5

  • 1郑启燕,施仲齐,王醒宇.核电站乏燃料水池遭受恐怖袭击后果评价[J].辐射防护,2005,25(1):45-50. 被引量:4
  • 2MILLER C, CUBBAGE A. The near-term task force review of insights from the Fukushima Dai- Ichi accident[R]. USA: NRC, 2011. 被引量:1
  • 3I NEI 06-i2, B. 5. b phase 2 3 submittal guide- lines, revision 2[R]. USA: NEI, 2006. 被引量:1
  • 4林诚格主编..非能动安全先进压水堆核电技术 下[M].北京:原子能出版社,2010:1362.
  • 5AP1000 design control document (Rev. 19)[M]. USA: Westinghouse Company, 2011. 被引量:1

二级参考文献9

  • 1施仲齐.广东省概率安全评价第Ⅲ级,事故后果和风险分析[M].国家核安全局,1990.. 被引量:1
  • 2Sailor V L,Perkins K R,et al. Severe Accidents in Spent Fuel Pools in Support of Generic Safety Issue 82. New Mexico: Sandia National Laboralories. NUREG/CR-4982. 1987. 被引量:1
  • 3Nombakhsh H P, Mial G, and Chang Z. Analysis of Spent Fuel Heatup Following Ices of Water in a Spent Fuel Pool. Sandia National Laboratories. NUREG/CR-6441.2OO2. 被引量:1
  • 4Chanin D I, Sprung J L, Ritchie L T, et al. Melcor Accident Consequence Code System ( MACCS ).NUREG/CR-4691. Sandia, 1990. 被引量:1
  • 5Nuclear Energy Institute. Aircraft Crash Impact Analyses Demonstrate Nuclear Power Plant's Structural Strength.Nuclear Energy Institute Press Release. 2002. 被引量:1
  • 6U.S. NRC. Accident Source Terms For Light-water Nuclear Power Plant. NUREG-1465. 1995. 被引量:1
  • 7Sprung J L, Ammerman D J, et al. Reexamination ofS pent Fuel Shipment Risk Estimates. New Mexico:Sandia National Laboratories. NUREG/CR-6672. 2000. 被引量:1
  • 8Travis R J, Davis R E, et al. A Safety and Regulatory Assessment of Generic BWR and PWR Permanently Shutdown Nuclear Power Plants. New Mexico: Sandia National Laboratories. NUREG/CR-6451. 1997. 被引量:1
  • 9章宗耀,傅先刚.大亚湾核电站18个月换料设计论证[J].核动力工程,2002,23(5):1-4. 被引量:6

共引文献3

同被引文献46

引证文献7

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部