摘要 获取理想手掌静脉图像是提高手掌静脉识别系统性能的前提条件。因此,本文设计一种非接触式全手掌静脉成像系统,该系统采用波长为850nm的圆头型近红外LED作为主动光源,同时选用与之灵敏度较高的OV7410摄像机并搭配光圈值为2.8、焦距为8mm的镜头。经实验表明,搭建的手掌静脉成像系统能够采集到清晰的全手掌静脉图像,为手部多模态特征融合提供了硬件平台。 Ideal palm vein imaging is the prerequisite of improving palm vein pattern recognition performance. It is designed a non- contact palm vein acquisition system in the paper. The system uses a wavelength of 85Onto round near-infrared LED as the active light source; meanwhile, uses the OV7410 camera with high sensitivity and aperture value of 2.8 with a focal length of 8mm lens. The experiment demonstrates the palm vein imaging device can acquire clear whole palm vein image, it provides hardware platform for multi-hand feature fusion.
出处 《微计算机信息》 2012年第10期46-47,108,共3页 Control & Automation
基金 基金颁发部门:国家自然科学基金 项目名称:在线单机非接触定焦成像手多模态信息融合技术 编号:(NO.60972123) 基金申请人:苑玮琦
关键词 手掌静脉 非接触 近红外LED 摄像机 palm vein non-contact near- infrared LED camera
  • 相关文献

参考文献6

  • 1R. Fuksis, M.Greitans,0. Nikisins, and M. Pudzs.Infraredimaging system for analysis of blood vessel structure. Electronicsand Electrical Engineering, 1(97):45-48,2010. 被引量:1
  • 2远藤利生,渡边正规,青木隆浩等.具有个人验证功能的处理器和操作设备.中华人民共和国国家知识产权局.G06K 9100.03121558.0.2004 年 2 月 4 日.1 页. 被引量:1
  • 3竹根秀一,木村诚也,中根元行.自动交易装置[P].中华人民共和国国家知识产权局.G07F9/00.2007100242562007年10月17日1页. 被引量:1
  • 4SHANIN M,BADAWI A,KAMEL M. Biometric authenticationusing fast correlation of near infrared hand vein patterns [J].International Journal of Biomedical Science,2007,2(3): 141-148. 被引量:1
  • 5李巍,邱跃洪,董佳.基于CMOS图像传感器的视频采集系统[J].微计算机信息,2008(11):277-278. 被引量:10
  • 6罗云瀚.近红外光谱无创伤血糖浓度测量的内部干扰因素分析[J].激光与红外,2008,38(5):465-467. 被引量:6

二级参考文献15

  • 1赵龙宝,范天翔,陆亨立.基于OV5017和CPLD的图像采集显示系统[J].微计算机信息,2005,21(06Z):104-105. 被引量:7
  • 2[2]Jan Bogaerts,Bart Dierickx,Guy Meynants,and Dirk Uwaerts,Total Dose and Displacement Damage Effects in aRadiation-Hardened CMOS APS,IEEE Transactions on electron devices.VOL.50,NO.1,Jan,2003 被引量:1
  • 3[5]IBIS5-A-1300 1.3M Pixel Dual Shuter Mode CMOS Image Sensor www.Fillfactory.com 被引量:1
  • 4[6]EZ-USB Manual Technical Reference www.cypress.com 被引量:1
  • 5Wulfert F Kok,W T Smilde A K.Influence of temperature on vibrational spectra and consequences for the predictive ability of multivariate models[J].Anal.Chem.,1998,70:1761-1767. 被引量:1
  • 6Houxin Cui,Lin An,Wenliang Chen,et al.Quantitative effect of temperature to the absorbance of aqueous glucose in wavelength range from 1200nm to 1700nm[J].Optics Express.,2005,13(18):6887-6891. 被引量:1
  • 7Laufer J,Simpson C R,Kohl M,et al.Effect of temperature on the optical properties of ex-vivo human dermis[J].Phys Med Biol.,1998 (43):2479-2489. 被引量:1
  • 8Larin K V,Motamedi M,Ashitkov T V.Specificity of noninvasive blood glucose sensing using optical coherence tomography technique:a pilot study[J].Phys.Med.Biol.,May.,2003,48(10):1371-1390. 被引量:1
  • 9Rinat O Esenaliev,Krill V Larin,lrina V Larina.Noninvasive monitoring of glucose concentration with optical coherence tomography[J].Optics Letters,2001,26 (13):992-994. 被引量:1
  • 10R D Rosenthal.Instrument for non-invasive measurement of blood glucose[P].USP1999,5,077,476. 被引量:1

共引文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部