电混凝深度处理垃圾渗滤液的试验研究 被引量:3

Advanced Treatment of Landfill Leachate by Electrocoagulation
原文传递
导出
摘要 采用铝电极对经生化处理的垃圾渗滤液进行电混凝深度处理。结果表明,在反应时间为45 min、电流密度为20 mA/cm2、极板间距为30 mm的最佳条件下,电混凝工艺对COD的去除率可达64%,对TP的去除率在90%以上,出水TP浓度可达到《生活垃圾填埋场污染控制标准》(GB 16889—2008)的要求,但出水COD和氨氮浓度都不能达标,还需增加后续处理工艺。 Landfill leachate pretreated by biochemical methods was treated by electrocoagulation using aluminum electrode. The results showed that under the optimal conditions of reaction time 45 rain, current density 20 mA/cm^2 and electrode distance 30 mm, the removal rates of COD and TP were 64% and more than 90% respectively. The effluent TP concentration met the Standard for Pollution Control on the Landfill Site for Domestic Waste (GB 16889 -2008 ). Subsequent treatment processes were necessary because the effluent concentrations of COD and ammonia nitrogen did not meet the discharge standards.
出处 《中国给水排水》 CAS CSCD 北大核心 2012年第17期99-101,共3页 China Water & Wastewater
基金 重庆大学研究生创新基金资助项目(CDJXS11210010) 重庆大学本科生创新基金资助项目(SRTP5605510)
关键词 电混凝 垃圾渗滤液 深度处理 electrocoagulation landfill leachate advanced treatment
  • 相关文献

参考文献4

  • 1Alinsafi A, Khemis M, Pons M N, et al. Electro-coagula- tion of reactive textile dyes and textile wastewater [ J ]. Chem Eng Process,2005,44 (4) :461 - 470. 被引量:1
  • 2Bayramoglu M, Kobya M, Eyvaz M, et al. Technical and economic analysis of electrocoagulation for the treatment of poultry slaughterhouse wastewater[J]. Sep Purif Tech- nol, 2006,51 ( 3 ) :404 - 408. 被引量:1
  • 3Adhoum N, Monser L. Decolnurization and remova- of phenolic compounds from olive mill wastewater by electro- coagulation[J]. Chem Eng Process,2004,43 (10) : 1281 - 1287. 被引量:1
  • 4Balasubramanian N, Madhavan K. Arsenic removal from industrial effluent through electrocoagulation [ J ]. Chem Eng Technol,2001,24(5) :519 -521. 被引量:1