摘要
目的探讨UF-100尿沉渣计数与显微镜计数结果的符合情况及影响因素,制订UF-100尿沉渣分析的显微镜复检规则。方法采用双盲法,对507份新鲜尿样本进行UF-100尿沉渣分析和显微镜计数,制订出UF-100尿沉渣分析的显微镜复检规则,并统计复检率。结果显微镜评价真阳性率:红细胞为58%,白细胞为74.4%,上皮细胞为59.2%,管型为8.0%,酵母样细胞为84.6%。据统计结果,制订出本室UF-100尿沉渣分析的显微镜10条复检规则,应用该规则,统计2008、2009和2010年复检率分别为22.2%、27.8%和24.2%。结论 UF-100尿沉渣分析仪检测结果漏检率低,但也带来较高的假阳性,建立适合本实验室UF-100尿沉渣分析的显微镜复检规则是必要的。
Objective To institute the criteria of urine sediment microscopic reexamination, we investigated the coincidence rate and influencing factors between UF-100 and microscopic examination. Methods 507 freshly urine samples were analyzed by the routine microscopic examination with the methods of double-blind. Meanwhile,the criteria of microscopic reexamination of UF 100 were instituted. Results the real positive rate of microscopic evaluation:the positive coincidence rate of RBC, WBC, EC,Cast, yeast- like cells was 58 %, 74.4 %, 59.2 %, 8.0% and 84.6 %, respectively. Based on those statistics results, 10 criterion of microscopic re examination were developed in our clinical lab. The total reexamination rate in 2008,2009 and 2010 were 22.2 %, 27.8% and 24.2 respectively. Conclusion Since UF-100 could not accurately analyze urine sediment and cause the false positive results, UF-100 could be used as a rapid screening procedure for automated urinalysis. To increase the accuracy of UF 100,it is necessary for us to develop the criterion of urine sediment microscopic reexamination.
出处
《重庆医学》
CAS
CSCD
北大核心
2012年第23期2394-2395,共2页
Chongqing medicine
关键词
UF-100
显微镜复检规则
符合率
UF- 100 criteria of microscopic reexamination
coincidence rate