摘要
以广东惠州平海发电厂有限公司2×1000 MW超超临界机组双切圆锅炉为例,介绍了特长非冷式烟温探针的原理及运行方式,分析了运行中出现故障的原因,给出了相应的处理措施。
Taking the double tangential circle boiler of 2×1000MW ultra supercritical unit of Guangdong Huizhou Pinghai Power Generation Company Limited as example,the principle and operation mode of the extra long non-cooled gas temperature probe were introduced.The reasons of faults occurred in operation were analyzed,and relevant treatment measures were given.
出处
《华电技术》
CAS
2012年第7期60-61,64,共3页
HUADIAN TECHNOLOGY
关键词
超超临界机组
双切圆锅炉
非冷式烟温探针
感应电压
继电器
ultra supercritical unit
double tangential circle boiler
non-cooled gas temperature probe
induced voltage
relay