期刊文献+

调节与辐辏因素导致视疲劳的诊断和治疗 被引量:9

Diagnosis and treatment of accommodative insufficiency and convergence insufficiency inasthenopia
原文传递
导出
摘要 视疲劳的临床表现复杂,因其症状的非特异性给临床诊断和病因治疗带来一定的困难。随着对该病的认识深入.发现其病因甚为复杂,并且往往是多因素混合导致发病。如果只是单纯的对症治疗效果并不理想,探寻病因进行对因治疗才是根本的治疗策略。目前已经明确多种因素可导致视疲劳,通过必要的眼科及视光学检查可确保明确且全面的病因诊断。目前针对视疲劳的病因治疗难易不同。一些病因只要去除和矫正就能避免视疲劳,而另一些就显得相对困难。调节和辐辏因素导致的视疲劳即属于后者。另一方面由于调节和辐辏检查的专科性,使得它们在视疲劳中的诊断和治疗具有一定的难度和特殊性。我们对目前调节和辐辏在视疲劳中的诊断和治疗现状进行总结,以期为临床诊治带来帮助。 Complicated and nonspecific clinical manifestations of asthenopia bring certain difficulties to clinical diagnosis and etiological treatment of it. With the in-depth understanding of the disease, its etiology is very complex and often multifactorial. Therapeutic effect is not ideal if only symptomatic treatment was delivered. Exploring the causes of the disease and treating them is the basic therapeutic strategy. It has become clear that many factors can lead to asthenopia. Some necessary ophthalmologic and optometry examinations can ensure etiological diagnosis. Different etiological treatments for asthenopia are with different difficulties. Only simply removal or correction of some causes can avoid symptoms, while others are relatively difficult, such as accommodation and convergence. On the other hand, the poor popularity of the examination of accommodation and convergence makes it difficult to find their effect on asthenopia and to treat them. We summarized the status quo of the diagnosis and therapy of accommodative insufficiency and convergence insufficiency in asthenopia, in order to contribute to the clinical work.
出处 《中华眼视光学与视觉科学杂志》 CAS 2012年第6期381-384,共4页 Chinese Journal Of Optometry Ophthalmology And Visual Science
关键词 视疲劳 调节不足 辐辏不足 诊断 治疗 Asthenopia Accommodative insufficiency Convergence insufficiency Diagnosis Therapeutics
  • 相关文献

参考文献2

二级参考文献28

  • 1Kolker D,Hutchinson R,Nilsen E.Comparison of tests of accommodation for computer users.Optometry,2002,73:212-220. 被引量:1
  • 2Nakaishi H,Yamada Y.Abnormal tear dynamics and symptoms of eyestrain in operators of visual display terminals.Occup Environ Med,1999,56:6-9. 被引量:1
  • 3Saito S,Miyao M,Kondo T,et al..Ergonomic evaluation of working posture of VDT operation using personal computer with flat panel display.Ind Health,1997,35:264-270. 被引量:1
  • 4Mocci F,Serra A,Corrias GA.Psychological factors and visual fatigue in working with video display terminals.Occup Environ Med,2001,58:267-271. 被引量:1
  • 5Woods V.Musculoskeletal disorders and visual strain in intensive data processing workers.Occup Med (Lond),2005,55:121-127. 被引量:1
  • 6de Wit GC.Evaluation of a new direct-comparison aniseikonia test.Binocul Vis Strabismus Q,2003,18:87-94. 被引量:1
  • 7Enoch J.Refractive aniseikonia:a source of binocular vision stress and asthenopia.J Refract Surg,1996,12:565-566. 被引量:1
  • 8John RG,Grisham JD,Ciuffreda KJ.Chapter 3:Heterophoria CaseAnalysis,In:Binocular Anomalies Diagnosis And Vision Therapy.4th ed.USA:Butterworth Heinemann,2002.70-97. 被引量:1
  • 9Jenkins RH.Characteristics and diagnosis of convergence insufficiency.Am Orthopt J,1999,49:7-11. 被引量:1
  • 10Carlson NB,Kurtz D,Health DA.Chapter 4:Functional Test.In:Carlson NB.Clinic Procedures for Ocular Examination,2nd ed.USA:Appleton&Lange Stamford,CT,1996.186-194. 被引量:1

共引文献25

同被引文献83

引证文献9

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部