期刊文献+

钢管陶粒混凝土柱火灾后轴压性能试验研究 被引量:7

Experimental study of post-fire axial compressive behavior of ceramsite concrete filled steel tubular columns
下载PDF
导出
摘要 对26根受火后的钢管陶粒混凝土短柱进行了轴压力学性能试验,试件考虑了钢管的几何参数、陶粒混凝土配合比及火灾条件等因素的变化。基于试验结果,分析了轻骨料钢管混凝土短柱受火后的轴压承载力、破坏形态及其他力学性能的变化及相关参数的影响规律。所讨论的主要影响参数包括试验最高炉温、最高炉温持续时间、钢管长细比、混凝土配合比等,并基于对试验数据的分析给出了轻骨料钢管混凝土短柱火灾后轴压承载力的计算公式。结果表明,以轻质材料———陶粒为骨料制成的钢管混凝土短柱受火后仍然具有较高的承载力和良好的延性,而当钢管表面响应温度超过500℃时,试件的轴压承载力出现了明显的下降。所给出的轻骨料钢管混凝土柱火灾后的轴压承载力计算公式可作为该类构件火灾后修复计算的参考依据。 This study conducted the axial compressive experiment of post-fire mechanical behavior of twenty six ce- ramist concrete filled steel short columns (CCFSSC) after exposure to fire, considering variation of the factors such as geometrical parameters, proportioning of the ceramist concrete and fire condition. On the basis of the test re- suits, the variations of residual axial compressive beating capacity, failure form and the other mechanical properties of the CCFSSC after exposure to fire were discussed, and effect of related parameters on the axial compressive char- acteristics of the short columns was analyzed. Main effect parameters involved here include the maximum value of fire temperatures, duration time of the temperature, slender ratio of the steel tubes and proportioning of the con- crete, etc. An expression of the axial compressive beating capacity of CCFSSC after exposure to fire was put for- ward based on the experimental results presented. The results show that the short columns still have good post-fire bearing capacity and ductility after exposure to fire, but the post-fire beating capacity of all the columns decreases significantly when the response temperature of surface of steel tubes is over 500~C. Furthermore, it is noted that the expression used for computation of axial compressive bearing capacity of CCFSSC can be used for giving a reference to post-fire restoration and corresponding computation of the columns after exposure to fire.
出处 《自然灾害学报》 CSCD 北大核心 2012年第3期191-197,共7页 Journal of Natural Disasters
基金 国家自然科学基金项目(51078187) 宁波市重点学科资助项目(SZX11060)
关键词 陶粒 钢管混凝土柱 火灾后轴压试验 承载力表达式 ceramsite concrete filled steel tubular column post-fire axial compressive experiment expression of bearing capacity
  • 相关文献

参考文献10

  • 1HAN Linhai, HUO Jingsi and WANG Yongchang. Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire [ J ]. Journal of Constructional Steel Research, 2005, 61 (7) : 882 - 901. 被引量:1
  • 2TAO Zhong, HAN Linhai, WANG Lingling. Compressive and flexural behaviour of CFRP - repaired concrete - filled steel tubes after exposure to fire[J]. Journal of Constructional Steel Research, 2007, 63(8) : 1116-1126. 被引量:1
  • 3YIN Jing, ZHA Xiaoxiong, LI Longyuan. Fire resistance of axially loaded concrete filled steel tube columns [ J ]. Journal of Constructional Steel Research, 2006, 62 (7) : 723 - 729. 被引量:1
  • 4HAN Linhai, LIN Xiaokang, WANG Yongchang. Cyclic performance of repaired concrete - filled steel tubular columns after exposure to fire [ J ]. Thin - Walled Structures, 2006, 44(10) : 1063 - 1076. 被引量:1
  • 5Espinos A, Gardner L, Mannel L. Fire behaviour of concrete filled elliptical steel columns [ J ]. Thin -Walled Structures, 2011,49 (2) : 239 - 255. 被引量:1
  • 6Kodur V K R. Performance - based fire resistance design of concrete - filled steel columns [ J ]. Journal of Constructional Steel Research, 1999, 51 (1): 21 -36. 被引量:1
  • 7林敏,刘殿魁.轴心受压钢筋混凝土柱等效火灾荷载的计算[J].自然灾害学报,2007,16(5):155-159. 被引量:1
  • 8白丽丽,王振清,苏娟,乔牧.火灾后钢筋混凝土梁的抗弯可靠性[J].自然灾害学报,2009,18(1):95-99. 被引量:7
  • 9韦灼彬,刘锡良.钢管陶粒混凝土在网架结构上的应用[J].钢结构,1994,9(3):211-214. 被引量:7
  • 10WANG Xintang, XIE Zhiguo, ZHOU Ming, et al. Experimental Study of Mechanical Behavior of Ceramsite Concrete Filled Steel Tubular Columns Subjected to Fire Load [ J ]. Advanced Materials Research, 2011,243 - 249 : 1228 - 1232. 被引量:1

二级参考文献22

  • 1林鹏,赵春梅,卢兆明,袁国杰.性能化火灾安全评估应用个案研究[J].自然灾害学报,2006,15(1):74-78. 被引量:3
  • 2谢狄敏,钱在兹.高温(明火)作用后混凝土强度与变形试验研究[J].工程力学,1996,13(A02):54-58. 被引量:23
  • 3G. TG. Mohamedbhai. The residual strength of concrete subjected to elevated temperatures[ J]. Concrete, 1983 (11 ) :22 -27P. 被引量:1
  • 4U. Schnerder. Rebiability of fire damaged structures, CIB W 14 Report[J]. Fire Safety Journal. 1990 15(4) :251 -338P. 被引量:1
  • 5R. Folic, V. Radonjanin, M. Malesev. The assessment of the structure of Novi Sad Open University damaged in a fire [ J ]. Construction and Building Materials. 2002 (16):427 - 440P. 被引量:1
  • 6共和国建设部.GB50068-2001建筑结构可靠度设计统一标准[s].北京:中国建筑工业出版社,2001. 被引量:1
  • 7Bing Chen, JuanyuLiu. Residual strength of hybrid-fiber-reinforced high-strength concrete after exposure to high temperatures , Cement and Con- crete Research. 2004(34) :1065 -1069P. 被引量:1
  • 8Zhan-Fei Huang, Kang-Hai Tan, Wee-Siang Toh, Guan-Hwee Phng. Fire resistance of composite columns with embedded l-sectionsteel--Effects of section size and load level. Constructional steel Research. 被引量:1
  • 9L. Sarvaranta and E. Mikkola. Fiber mortar composites under fire conditions: effect of ageing and moisture content of specimens, Materials and Structures, V 27,1994:532 -538P. 被引量:1
  • 10Madsen H O, Krenk S, Lind N C. Methods of Structural Safety. New Jersey; Prentice-Hall, Inc. ,1986. 被引量:1

共引文献12

同被引文献63

引证文献7

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部