介绍了蒸发式冷凝器制冷机组中3种不同形式冷凝器的节能效果,以R22压缩制冷循环为例,可知冷凝温度每降低1℃,理论压缩机功耗将减少2%~3%;且蒸发式制冷机组冷却水量比水冷式少,节约循环水泵能耗。将室内排风和凝结水分别作为蒸发式冷凝器的部分送风和冷却水,可降低制冷机组的冷凝温度,进一步达到节能目的。
The energy-saving effect of three different condensers for the evaporative condenser's refrigerating unit was introduced and compared.Taking R22 refrigeration cycle for example,the theoretical compressor power consumption cuts down by 2% to 3% theoretically while condensation temperature reduces 1℃.Cooling water flow of the evaporative condenser is less than water-cooled condenser's,this makes power consumption of circulating water pump saved.Taking indoor exhaust and condensed water for the evaporative condenser can lower the condensation temperature of refrigerating unit as required.
出处
《化工机械》
CAS
2012年第1期1-4,共4页
Chemical Engineering & Machinery
基金
亚热带建筑中央空调综合节能示范工程(2007A04020004
2007C13G0161)
地下车库空调节能减排技术研究(2009ZC13)
关键词
蒸发式冷凝器
制冷空调
节能
余冷
evaporative condenser
refrigerative air-conditioning
energy-saving
residual cool