pH值对水厂排泥水的调质作用研究 被引量:3

pH regulation for the characters of sludge water in waterworks
下载PDF
导出
摘要 通过混凝试验,以沉降比、上清液浊度、氨氮和CODMn作为考察排泥水沉降浓缩处理性能的指标,研究了pH值调质对污泥沉降性能的影响。结果表明:在弱酸性(pH=6.0~6.8)条件下,使用阴离子型聚丙烯酰胺(PAM)能有效地改善污泥沉降浓缩后的上清液水质;进行pH值调质时,投酸量与排泥水的浓度有关;运行中应严格控制pH值的调节,pH<5时不利于沉降,pH>7时调质效果不明显。 The influence of pH regulation on the performance of sludge settlement was investigated, which the settlement ratio, turbidity of supernatant, ammonia nitrogen and CODMn as the indexes in the coagulation experiment. The results showed that the water quality of supernatant after sludge settlement and concentration could be improved effectively with anionic PAM under weak acidic condition (pH 6.0 to 6.8). The acidic dosage had relation to the concentration of sludge water when pH was regulated. The pH regulation should be strictly controlled, it could not be favorable to settlement when pH was lower than 5, and the effect of regulation was not obvious when pH was higher than 7.
出处 《供水技术》 2012年第2期18-21,共4页 Water Technology
关键词 水厂 排泥水 PH值 浓缩 调质 waterworks sludge water pH value concentration regulation
  • 相关文献

参考文献5

二级参考文献2

  • 1[1]Vesilind P A. The role of water in Judge dewatering. Water Environment Research, 1994, 66(1) : 4 被引量:1
  • 2[2]高廷耀主编.水污染控制工程(下册).北京:高等教育出版社,1990 被引量:1

共引文献29

同被引文献38

引证文献3

二级引证文献5