期刊文献+

基本单分散气溶胶透过率测试中真实值的计算 被引量:1

Computation of true data using the experiment penetration curve of moderately monodisperse aerosol
原文传递
导出
摘要 通过对高效、超高效滤料透过率测试台工作原理的分析得到:利用基本单分散粒子作为气溶胶测得的透过率关系与滤料真正的透过率-粒径曲线有区别,实际上是所使用实验气溶胶的综合透过率。详细研究了真正透过率与实验透过率的关系、误差和偏离产生原因,最终提出了一种独特的计算方法,实现了根据实验得到的表观透过率-粒径关系,就可以计算出真实透过率-粒径曲线,并得到了采用较为理想的实验气溶胶测试出的真实透过率的实际验证,这将大大提高高效、超高效滤料性能测试台的精度,拓展了其应用范围,为高效滤料的过滤理论和应用研究提供了比较理想的测试手段。 By analyzing the principle of DOP media tester for the high-efficiency particulate air filter(HEPA) and ultra-low penetration air(ULPA) filter,it was found that the measured penetration with moderately monodisperse aerosol is not the true penetration for a given particle size,but the integrated penetration of a given test aerosol.The relationship between the true penetration of a single size and the measured penetration was studied.And the reason that results in the deviation between them was analyzed.A special computation method was put forward to obtain the true penetration of the given single particle size using the experimental data of the overall penetration–particle size relationship and the particle size distribution.The validity of the computation method was demonstrated using the experimental data.This method will greatly improve the accuracy of the HEPA and ULPA filter media DOP testers and broaden their applications.A high quality testing mean will be achieved for the theoretical and applied research of the high-efficiency filter media.
出处 《环境工程学报》 CAS CSCD 北大核心 2012年第3期971-976,共6页 Chinese Journal of Environmental Engineering
关键词 过滤 单分散 气溶胶 计算方法 透过率 粒径 分布 filtration monodisperse aerosol computation method penetration particle size distribution
  • 相关文献

参考文献16

  • 1中华人民共和国国家标准.GB6166-85,高效滤料性能试验方法透过率和阻力,北京:中国标准出版社,1985. 被引量:1
  • 2Cheng X.Y.,Zhang J.K.The comparison of turbine oilmethod with other methods.Proceedings of the 20th DOE/NRC Nuclear Air Cleaning Conference,Boston,MA,1988.1146-1165. 被引量:1
  • 3Yang S.,Lee G.W.Filtration characteristics of a fibrousfilter pretreated with anionic surfactants for monodispersesolid aerosols.J.Aerosol Sci.,2005,36(4):419-437. 被引量:1
  • 4Maus R.,Umhauer H.Collection efficiencies of coarse andfine dust filter media for airborne biological particles.J.Aerosol Sci.,1998,28(3):401-415. 被引量:1
  • 5Vaughan N.P.The generation of monodisperse fibers ofcaffeine.J.Aerosol Sci.,1990,21(3):453-462. 被引量:1
  • 6Boskovic L.,Agranovski I.E.,Altman I.S.,et al.Filterefficiency as a function of nanoparticle velocity and shape.J.Aerosol Sci.,2008,39(7):635-644. 被引量:1
  • 7Boskovic L.,Agranovski I.E.,Braddock R.D.Filtrationof nanosized particles with different shape on oil coated fi-bers.J.Aerosol Sci.,2007,38(12):1220-1229. 被引量:1
  • 8Boskovic L.,Altman I.S.,Agranovski I.E.,et al.Influ-ence of particle shape on filtration processes.Aerosol Sci.Technol.,2005,39(12):1184-1190. 被引量:1
  • 9林秉乐,冯佩明,徐立大,张利群.高效、超高效滤料性能测试台的研制[J].中国粉体技术,1999,5(3):1-3. 被引量:5
  • 10McMurry P.H.A review of atmospheric aerosol measure-ments.Atmospheric Environment,2000,34(12-14):1959-1999. 被引量:1

二级参考文献1

  • 1林秉乐 Liu B Y H.国产采样和高效滤料性能试验[J].洁净技术,1987,(4). 被引量:1

共引文献4

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部