摘要 通过对国内外相关研究成果的整理和分析,依据混凝土火灾爆裂危险性的影响因素,建立了混凝土结构火灾爆裂危险性分级评价体系。根据爆裂危险度值的大小将混凝土结构的爆裂危险性分为5级。爆裂危险性预测与实测结果的一致性显示了所提混凝土火灾爆裂危险性分级评价体系的有效性,可为混凝土构件和结构减灾防火设计提供参考。 Based on an analysis of domestic and overseas former research results, and considering the factors influ- encing explosive spalling, a hierarchical system for assessing the fire spalling risk of concrete structures was estab- lished. Five levels of spalling risk were defined in this system by the total risk value of the concrete structure. Good agreement between the results of spalling risk prediction and the fire test shows the efficacy of the proposed system in assessing the fire spalling risk of concrete structures, which could provide a reference for the fire resistance design of concrete structures.
作者 李荣涛
出处 《自然灾害学报》 CSCD 北大核心 2012年第1期204-210,共7页 Journal of Natural Disasters
基金 国家自然科学基金项目(50278012) 辽宁省教育厅基金项目(2009A064 L2011215)
关键词 混凝土结构 火灾 爆裂 危险性评估 concrete structures fire explosive spalling risk assessment
  • 相关文献

参考文献21

  • 1Malhotra H L. Spalling of Concrete in Fires[ R]. CIRIA Technical Note 118, 1984. 被引量:1
  • 2Khoury G A. Effect of fire on concrete and concrete structures[ J]. Progress in Structural Engineering and Materials, 2000, 2 (4) : 429 -447. 被引量:1
  • 3Anderberg Y. Spalling phenomena of HPC and OC [ C ]//National Institute of Standards and Technology. International Workshop on Fire Performance of High - Strength Concrete. Gaithersburg, MD : NIST Special Publication 919, 1997, B. 3 : 69 - 73. 被引量:1
  • 4Brcunese A J, Fellinger J H H. Spalling of Concrete and Fire Protection of Concrete Structures[ R]. TNO Building and Construction Research Report, 2004. 被引量:1
  • 5Schneider U. Properties of Materials at High Temperatures- concrete[ R]. 3rd ed. RILEM, 1986. 被引量:1
  • 6Khoylou N. Modelling of Moisture Migration and Spalling Behaviour in Non - uniformly Heated Concrete [ D ]. London: University of London, 1997. 被引量:1
  • 7Hertz K D. Limits of spalling of fire-exposed concrete[J]. Fire Safety Journal, 2003, 38(2) : 103 - 116. 被引量:1
  • 8石东升,王海波,刘曙光.影响火灾下混凝土爆裂因素的试验研究[J].内蒙古工业大学学报(自然科学版),2007,26(2):129-135. 被引量:13
  • 9Kodur V K R. Spalling in high strength concrete exposed to fire--concerns, causes, critical parameters and cures [ C ]//ASCE Structures Congress Proceedings. Philadelphia, PA : American Society of Civil Engineers ,2000 : 1 - 8. 被引量:1
  • 10Newman J, Choo B S. Advanced concrete technology[ M]. Oxford: Elsevier Ltd, 2003. 被引量:1

二级参考文献44

  • 1李卫,过镇海.高温下砼的强度和变形性能试验研究[J].建筑结构学报,1993,14(1):8-16. 被引量:256
  • 2钮宏,马云凤,姚亚雄.轻骨料混凝土构件抗火性能的研究[J].建筑结构,1996,26(7):29-33. 被引量:6
  • 3[1]Schneider U. Concrete at High-Temperatures--a General Review. Fire Safety Journal, 1988, 13(1): 55~68 被引量:1
  • 4[10]Yin Chan Sammy,Peng Gaifei,Anson Mike. Fire Behavior of HighPerformance Concrete Made with Silica Fume at Various Moisture Contents. ACI Materials Journal, 1999 ( 5 ~ 6) 被引量:1
  • 5[11]Hertz K D. Danish Investigations on Silica Fume Concretes at Elevated Temperatures. ACI Materials Journal, 1992(7 ~ 8) 被引量:1
  • 6索默H.高性能混凝土的耐久性[M].北京:科学出版社,1998.145-156. 被引量:9
  • 7宿晓萍.火灾后约束高强混凝土本构关系与已修复结构抗震性能研究[M].哈尔滨:哈尔滨建筑大学,2000.18-19. 被引量:3
  • 8马忠诚.火灾后钢筋混凝土结构损伤评估与抗震修复[M].哈尔滨:哈尔滨建筑大学,1997.45-68. 被引量:3
  • 9Gawin D,Baggio P,Schrefler BA.Modelling heat and moisture transfer in deformable porous building materials.Arch Civil Engrg,1996,42:325~349 被引量:1
  • 10Gawin D,Majorana CE,Schrefler BA.Numerical analysis of hygro-thermal behaviour and damage of concrete at high temperature.Mechanics of Cohesive-Frictional Materials,1999,4:37~74 被引量:1