期刊文献+

考虑暂态频率特性的孤立电网低频减载方法 被引量:4

An under-frequency load shedding method adapted to isolated power grids considering transient frequency characteristics
下载PDF
导出
摘要 针对孤立电网运行频率波动范围较大且负荷有限的特点,提出一种考虑系统暂态频率特性的孤立电网低频减载方法.该方法采用较低的频率启动值及较少的启动轮次;根据实际系统暂态频率特性,对于频率启动值较大的轮次,采用较长的动作时限;并采用最低频率轮先动作其他轮间并行或的动作逻辑;且在特殊情况下,采用低频减载与快速连切负荷相结合的措施确保系统频率稳定.应用实例分析表明该方法能在很大程度上提高低频减载的有效性,避免低频减载装置无谓动作,有利于孤立电网运行的安全稳定. According to large frequency fluctuation range and limited load in the operation of isola- ted power grids, an under-frequency load shedding method adapted to the isolated grid is presen- ted in this paper with transient frequency characteristics considering. The method adopts lower frequency starting value and less starting rounds. Based on the transient frequency characteristics, longer tripping time is used at higher frequency starting value. The lowest frequency round operates first, and others operate in parallel. In particular conditions, an under-frequency load shedding (UFLS) with accelerated load shedding method is used to ensure the stability of frequency. The application example analysis results shows that the method can improve the efficiency of under frequency load shedding, avoid unnecessary operation of the UFLS device, which has great significance for the stable operation of isolated grids.
出处 《电力科学与技术学报》 CAS 2011年第4期69-73,共5页 Journal of Electric Power Science And Technology
基金 国家自然科学基金(50907039) 西藏电力有限公司科技项目(SJB-2010-001) 河北电力公司科技帮扶项目(KJ-2010-112) 上海市科委国内科技合作项目(11195802200)
关键词 孤立电网 低频减载 频率波动 暂态频率特性 isolated power grid under frequency load shedding (UFLS) frequency fluctuation transient frequency characteristics
  • 相关文献

参考文献9

二级参考文献47

共引文献76

同被引文献15

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部