期刊文献+

高扭矩植入种植体的近期疗效的对比研究 被引量:7

The comparing study on the early clinical results of implants with higher insertion torque value
下载PDF
导出
摘要 目的:对比高扭矩和常规扭矩植入的种植体在负重前骨吸收(MBR)水平和近期累积存留率的差异,探讨高扭矩植入种植体的可行性及并发症的预防。方法:以35例后牙区牙列缺损,接受种植修复的患者为研究对象,共有55枚Bio-Med 3i Osseotite Tapered Certain种植体被纳入研究。种植体按植入扭矩值(ITV)分入A、B组,A组15枚种植体,ITV≤50N.cm,B组40枚种植体,50N.cm≤ITV≤90N.cm。采用埋置术式完成手术,术后即刻平行投照根尖片确定种植体周骨水平的基线,术后3~5个月复查时,再次投照种植体的根尖片,对比骨水平变化,得到负重前种植体MBR数据。结果:种植体植入术后3~5个月,A、B组间MBR值无统计学差异,全部种植体于二期术后一个月内完成固定烤瓷修复,平均随访11个月,观察期内种植体存留率100%。结论:观察期内高扭矩植入种植体不会引起种植体周骨吸收加重,近期疗效满意,值得进一步观察其远期疗效。 Objective: To compare the difference of implants,inserted with normal or higher insertion torque value(ITV),on marginal bone resorbtion(MBR) before loading and early survival rates,discussing the feasibility and complication preventing on implants insertting with higher ITV.Methods: 35 patients with missed teeth at the posterior region were taken part in this research program,and a total of 55 3i(r)Osseotite Tapered Certain was divided into A or B group based on implants' insertion torque value(ITV).Group A(15 implants),the controlled group,ITV≤50N.cm;Group B(40 implants),the experiment group,50N.cm≤ITV≤90N.cm.All implants accepted submerged surgery,and have been taken intraoral radiographs immediately after surgery and 3-5 month after surgery for MBR calculating.Results: There are no different between group A and B on MBR 3-5 months after surgery,all implants received fixed porcelain restoration 1 month after second stage surgery,within the observation period,no implants failed,the cumulatting survival rate is 100% in both groups.Conclusions: implants insertting with higher torque would not cause to worse MBR,has a good clinical result,and be worth to go on research on longer observation period.
出处 《中国口腔种植学杂志》 2011年第4期207-210,213,共5页 Chinese Journal of Oral Implantology
基金 罗湖区科技局立项 编号:2010107
关键词 牙种植 植入扭矩值 种植体周骨吸收 dental implant insertion torque value marginal bone resorbtion
  • 相关文献

参考文献16

  • 1Irinaks T,Wiebe C,Initial torque stability of a new bone condensing dental implant:a cohort study of 140 on seductively placed implants.J of Oral Implantology,2009;35:277-282. 被引量:1
  • 2Ueda M, Matsuki M, Jacobsson M, et al.Relationship between insertion torque and removal torque analyzed in fresh temporal bone.Int J Oral Maxillofac Implants.1991;6:442-447. 被引量:1
  • 3余粤海,叶萍,邱小燕,张新薇,许建英,翁达龙.两段式种植系统采用非埋置术式疗效的对比研究[J].中国口腔种植学杂志,2011,16(2):101-105. 被引量:5
  • 4Drago C J,Lazzara RJ.Immediate occlusal loading of Osseotite implants in mandibular edentulous patients:a prospective observational report with 18-month data.J Prosthodont.2006;15:187-194. 被引量:1
  • 5Ottoni JM,Oliveira ZF,Mansini R,et al.Correlation between placement torque and survival of singletooth implants.Int J Oral Maxillofac Implants.2005;20:769-776. 被引量:1
  • 6Rabel A,Kohler SG,Schmidt-Westhausen AM.Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.Clin Oral Investig.2007;11:257-265. 被引量:1
  • 7Olsson M,Friberg B,Nilson H,Kultje C.MkⅡ-a modified self-tapping Branemark implant:3-year results of a controlled prospective pilot study.Int J Oral Maxillofac Implants.1995;10:15-21. 被引量:1
  • 8Ivanoff CJ, Grondahl K, Bergstrom C, et al.Influence of bicortical or monocortical anchorage on maxillary implant stability:a 15-year retrospective study of Branemark System implants.Int J Oral Maxillofac Implants.2000;15:103-110. 被引量:1
  • 9O'Sullivan D,Sennerby L,Meredith N.Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants.Clin Oral Implants Res.2004;15:474-480. 被引量:1
  • 10Petrie CS,Williams JL.Comparative evaluation of implant designs:influence of diameter,length,and taper on strains in the alveolar crest.A threedimensional finite-element analysis.Clin Oral Implants Res.2005;16:486-494. 被引量:1

二级参考文献24

  • 1柳忠豪,徐欣,许胜,孙爱杰,卢志山,刘利苹.即刻种植与种植体早期加载的临床研究[J].中华口腔医学杂志,2006,41(4):196-199. 被引量:9
  • 2[1]Cochran DL,Buser D,ten Bruggenkate CM,et al.The use of reduced healing times on ITI implants with a sand blasted and acid-etched (SLA) surface:early results from clinical trialson ITI SLA implants[J].Clin Oral Impl Res,2002,13:144~153 被引量:1
  • 3[2]Meredith N.Assessment of implant stability as a prognostic determinant[J].International journal of Prosthodontics,1998,11:491~501 被引量:1
  • 4[3]Bahr W.The effects of pre-tapping on the miniscrew-bone interface in the midface [J].J Craniomaxillofac Surg,1989,17:337 被引量:1
  • 5[4]Berglundh T,Abrahamsson I,Lang N.P,et al.De novo alveolar bone formation adjacent to endosseous implants:A model study in the dog[J].Clin Oral Impl Res,2003,14(20):251~262 被引量:1
  • 6[5]Moller W,Lowicke G,Naumann H.Reconstruction of the pars alveolaris with mouded and compressed spongy substance [J].Zahn-,Mund-Kieferheilkunde, 1985,73:464~470 被引量:1
  • 7[6]Nkenke E,Kloss F,Wiltfang J,et al. Histomorphometric and fluorescencemicroscopic analysis of bone remodelling af ter installation of implants using an osteotome technique[J].Clin Oral Impl Res,2002,13:595~602 被引量:1
  • 8Engquist B, Astrand P, Anzen B, et al. Simplified methods of implant treatment in the edentulous low- er jaw. A controlled prospective study. Part I: one- stage versus two-stage surgery. Clin Implant Dent Relat Res. 2002,4 (2) :93-103. 被引量:1
  • 9Oliveira RR, Novaes AB, Taba M. et al, Bone re- modeling Adjacent to morse cone-connection im- plants with platform switch: a fluorescence study in the dog mandible, Int J Oral Maxillofac Implants, 2009,24 (2) :257-266. 被引量:1
  • 10Ericsson I, Randow K, Nilner K, Petersson A, et at. Some clinical and radio-graphical features of sub- merged and non-submerged titanium implants. A 5- years follow-up study, Clin Oral Impl Res 1997,8 (5) :422-426. 被引量:1

共引文献10

同被引文献118

引证文献7

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部