期刊文献+

沼气混合制冷剂循环液化流程与设备分析 被引量:4

Exergy Analysis of Mixed-refrigerant Cycle Liquefaction Process of Biogas
下载PDF
导出
摘要 以天然气液化设备为模型,利用Aspen HYSYS软件,设计小型混合制冷剂液化沼气流程,对该流程进行数值模拟,根据PR方程计算出沼气的泡点与露点以及液化率、能耗等。在热力学分析的基础上,计算流程各设备损失,分析产生设备损失的原因,提出降低设备损失的方法。依据模拟结果,建立实验平台对降低损失方法进行验证,结果表明:小型混合制冷剂液化沼气流程具有可行性,液化过程中能耗和损失最大的设备是压缩机,利用储液罐上端的闪蒸气预冷混合制冷剂的方法可使压缩机和冷却器的损失分别减少12.2%和27.2%。 The pint-sized gas mixed-refrigerant liquefaction process was designed to analyze the exergy loss by using Aspen HYSYS software.The temperature and the pressure of bubble point and the dew-point were obtained from the PR equation,and the liquefied rate and energy consumption was calculated.Subsequently,the exergy loss was calculated via the thermodynamic analysis,and the methodology for reducing exergy loss was approached.An experiment was conducted to measure the exergy loss.The results showed that small gas mixed-refrigerant liquefaction process was feasible,while the largest exergy loss in the liquefaction process was compressor.With flash evaporation pre-cooled freezing medium on the top of storage tank,the reduction of exergy loss for compressor and chiller were 12.2% and 27.2%,respectively.
出处 《农业机械学报》 EI CAS CSCD 北大核心 2011年第12期138-142,190,共6页 Transactions of the Chinese Society for Agricultural Machinery
基金 山东省自然科学基金资助项目(ZR2009EZ001)
关键词 沼气 液化 混合制冷剂 ASPEN HYSYS 损失 Biogas Liquefaction Mixed-refrigerant Aspen HYSYS Exergy loss