考察了在不同温度、不同浓缩倍数条件下陶瓷膜对废乳化液的处理效果及渗滤液通量变化情况。结果表明:温度为30℃时,CODCr和矿物油的截留率均达90%以上。此外还确定了膜的清洗方法,为实际应用提供基础数据。
In this paper, waste emulsion was treated by ceramic membrane. At different temperatures and different volume reduction functions, the treatment result and the change of permeate flux was researched. The result showed that the retention of COD_(Cr) and oil is more than 90% at 30. In addition, the method of membrane cleaning was ascertained and the base data for practical application were supplied.
出处
《城市环境与城市生态》
CAS
CSCD
2005年第4期9-10,共2页
Urban Environment & Urban Ecology