摘要
建立了烟用白乳胶中残余乙酸乙烯酯的静态顶空-气相色谱-质谱(SHS—GC—MS)内标定量测定方法。样品经80℃下15min静态顶空后,以2-己酮为内标,采用HP—INNOWAX柱,GC—MS/选择离子监测(SIM)模式检测,内标法定量。结果表明:方法的检测限、加标回收率和相对标准偏差(RSD)分别为0.63mg/kg,104%~107%和2.5%~4.9%。该方法具有简单快速、准确灵敏等特点,适合于烟用白乳胶中残余乙酸乙烯酯的定量分析。
A method for determining the residual vinyl acetate in polyvinyl acetate emulsion adhesive for cigarette by static headspace-gas chromatography-mass spectrometry (SHS-GC/MS) with internal standard was developed. The adhesive sample was treated at 80℃ for 15 min with 2-hexanone as internal standard, the extract was separated by a HP-INNOWAX column, determined by MS and quantified by the internal standard under selected ion monitoring (SIM) mode. The results showed that the recoveries of the method ranged from 104% to 107% with the relative standard deviation (RSD) of 2.5 to 4.9% and the limit of detection of 0.63 mg/kg. The method is accurate, slmple, rapid, and suitable for the analysis of residual vinyl acetate in cigarette emulsion adhesives.
出处
《烟草科技》
EI
CAS
北大核心
2011年第11期32-35,共4页
Tobacco Science & Technology
关键词
静态顶空
气相色谱-质谱
乙酸乙烯酯
烟用白乳胶
Static headspace
Gas chromatography-mass spectrometry
Vinyl acetate
Polyvinyl acetate emulsionadhesive for cigarette