摘要
目的评价两种全自动血细胞分析仪(KX一21与ABXPENTRA60)的性能,以验证不同仪器测定结果的准确性和一致性。方法按照国际血液学标准化委员会(ICSt[)有关规定,对KX一21与ABXPENTRA60KX一21全自动血细胞分析仪从携带污染率、精密度、线性、及与ABXPENTRA60A全自动血细胞分析仪相关性和白细胞分类准确性等方面进行评价。结果KX一21的批间、批内精密度及总精密度变异系教(CV%)均在可接受范围内;各分析参数的携污带染率均〈1.O%;与ABXPENTBA60对比分析,各项参数相关性良好;白细胞分类准确性符合要求。结论KX一21与ABXPENTRA60血液分析仪性能良好,检测结果准确可靠,在临床应用中结果可以互认。
Objective To evaluate the main performance of two kinds of automatic blood cells analyzer, to ensure the accuracy and consis- tency of these two instruments. Methods According to the rclated regulation of international hematology standardization commission (ICSH), the performances of KX - 21 and CD3200 hematology analyzer were evaluated in regards to precision, carry - over rate, lineality, the correlation with ABX PEIVI'RA 60 Heamatology analyzer and the accuracy of WBC classification. Results Tile CV value of with - and between - Batch precision and that of the total precision of KX - 21 and CD3200 were all within the designed range.The carry - over rate was lower than 1. 0%. The correlation between ABX PENTRA 60 and thcst two intrument was satisfactory.The accuracy of WBC classification meets the require- me,it. Conclusion The performances of KX - 21 and CD3200 hematology analyzer have been proved to be accurate and reliable in test results.
出处
《医学检验与临床》
2011年第5期62-64,共3页
Medical Laboratory Science and Clinics
关键词
血液分析仪
精密度
携带污染率
相关性
准确性
Blood cells analyzer
Precision
Carry - over rate
Correlation
Accuracy