摘要 介绍了靠近身体使用的无线通信设备SAR评估方法适用范围、测量系统规格;详细解读SAR评估规程,包括人体组织模拟液和系统准备、待测设备准备、电池一次充电进行多次SAR测量的方法、待测设备相对于模型的位置布置、测试频率、要执行的测量、测试步骤、多频段同时发射的待测设备的测量以及后处理。 The applicability and measurement system specification of SAR evaluation method for wireless communication equipment used in close proximity to the human body were introduced.The SAR assessment agreements were explained,including preparation of human tissue-equivalent liquid and system,preparation of DUT,multiple SAR measurements using a single-charged battery,setup position of the DUT in relation to the phantom,test frequencies,tests to be performed,measurement procedure,procedures for testing of DUTs with simultaneous multi-band transmission and post-processing.
出处 《安全与电磁兼容》 2011年第5期16-20,21,共6页 Safety & EMC
关键词 SAR 无线通信设备 模型 组织模拟液 SAR wireless communication device phantom tissue-equivalent liquid
  • 相关文献

参考文献3

  • 1IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures- Part2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close prox- imity to human body (frequency range of 30 MHz to 6 GHz)[S]. 2010. 被引量:1
  • 2IEC 62209-1:2005 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures-Partl: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)[S]. 2005. 被引量:1
  • 3信息产业部电信研究院,YD/T1644-2007手持和身体佩戴使用的无线通信设备对人体的电磁照射-人体模型、仪器和规程第1部分:靠近耳边使用的手持式无线通信设备的SAR评估规程(频率范N300MHz-3GHz)[S].北京:标准出版社,2007. 被引量:1

同被引文献3

  • 1FCC KDB Publication 865664:SAR Measurement Require-ment for 3-6GHz[S].2006. 被引量:1
  • 2IEC 62209-2:2010 Human exposure to radio frequency fieldsfrom hand-held and body-mounted wireless communicationdevices-Human models,instrumentation,and procedures-Part1:Procedure to determine the specific absorption rate(SAR)for hand-held devices used in close proximity to the humanbody(frequency range of 30 MHz to 6 GHz)[S].2010. 被引量:1
  • 3IEEE C93.5-2002 IEEE Recommended Practice for Measure-ments and Computations of Radio Frequency ElectromagneticFields with Respect to Human Exposure to Such Fields,100 kHz-300 GHz[S].2002. 被引量:1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部