摘要 目的研究心率快慢与心律不齐对64排CT冠状动脉造影图像质量的影响。方法对接受64排CT冠状动脉造影患者84例行前瞻性研究,其中女26例,男58例;平均年龄(65.37±10.44)岁。在扫描R-R间期内以5%间隔重建图像。心率变化程度以扫描期间各心率的标准差进行评价。图像质量分为四级(1级无运动伪影,-4级不能诊断)。对心率快慢及心律变化程度与图像质量的关系行Pearson相关分析。结果扫描时平均心率为(74.63±11.33)次/min,心律变化为(3.52±2.41)次/min。1 836个节段中有1 821个节段为可诊断图像。右冠状动脉与前降支图像质量与心率快慢无相关性。左旋支图像质量随着心率的增快而变差(r=0.384,P<0.05)。心律不齐程度对图像质量有明显影响(r=0.710,P<0.001)。在心率>80次/min时,最佳重建时相由舒张期改为收缩期。结论 64排CT可在高心率条件下提供可诊断图像,但适当控制心率,可以明显改善64排CT冠状动脉成像质量。 Objective To investigate the influence of average heart rate and heart rate variability on image quality using 64-section computed tomographic(CT) coronary angiography.Methods There were 84 patients(26 women,58 men;mean age,65.37±10.44 years) who underwent 64-section CT coronary angiography with retrospective electrocardiographic gating.Data sets were reconstructed in 5% steps within the exposure windows.Heart rate variability was calculated as standard deviation during scanning.Image quality was evaluated by 4-point method(1: no motion artifacts to 4: can not be evaluated).Pearson correlation analysis was performed to compare image quality with average heart rate and heart rate variability.Results Mean heart rate was 74.63±11.33 beats per minute(bpm),with variability of 3.52±2.41 bpm.Diagnostic image quality(score3) was attained in 1821 of 1836 segments after optimal reconstruction.There was no correlation between mean heart rate and image quality for all segments of the right coronary and left anterior descending arteries,but there was a significant correlation for left circumflex artery(r=0.384,P0.05).Heart rate variability was correlated with image quality overall(r=0.710,P0.01).The optimal reconstruction intervals shifted from diastole to systole when heart rate80 bpm.Conclusion 64-section CT can provide diagnostic image quality within a wide range of heart rates.However,average heart rate and heart rate variability is suggested to reduce artifacts.
作者 李成 宋伟
出处 《实用医药杂志》 2011年第10期875-878,共4页 Practical Journal of Medicine & Pharmacy
关键词 冠状动脉 计算机体层扫描 图像质量 Coronary artery Computed tomography Image quality
  • 相关文献

参考文献4

二级参考文献21

  • 1Achenbach S,Giesler T,Ropers D,et al.Detection of coronary artery stenoses by contrast-enhanced,retrospectively electro cardiographicallygated,multislice spiral computed tomography.Circulation,2001,103:2535 被引量:1
  • 2Nieman K,Oudkerk M,Rensing BJ,et al.Coronary angiography with multi-slice computed tomography.Lancet,2001,357:599 被引量:1
  • 3Achenbach S,Ulzheimenorr S,Baum U,et al.Noninvasive coronary angiography by retrospectively ECG-gated multi-slice spiral CT.Circulation,December,2000,102:2823 被引量:1
  • 4Ropers D,Baum U,Plhle K,et al.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and mutiplanar reconstruction.Circulation,2003,107:664 被引量:1
  • 5Rumberger JA,Kaufman L.A rosetta stone for coronary calcium risk stratification:agatston,volume,and mass scores in 11490 individuals.AJR,2003,181:743 被引量:1
  • 6Thomas J,Nasreddin D,Thomas D,et al.Techniques for the Detection of Coronary Atherosclerosis:multi-detector row CT coronary angiography.Radiology,2002,223:212 被引量:1
  • 7Hong C,Backer CR,Huber A,et al.ECG gated reconstructed multidetector row CT coronary angiography:effect of varying trigger delay on image quality.Radiology,2001.220:712 被引量:1
  • 8Gerber TC,Kuzo RS,Lane GE,et al.Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography.Journal of Computer Assisted Tomography,2003,27:62 被引量:1
  • 9Wang ZQ,Zhu H,Xia K,et al.Preliminary application of MSCT of coronary artery.Journal of Computed Tomography,2001,10:10 被引量:1
  • 10Sha He,Ruping Dai,Yao Chen,et al.Optimal ECG triggering phase to reduce motion artifact in electron beam tomography coronary artery scans.Acad Radiol,2001,8:48 被引量:1

共引文献24

同被引文献34

引证文献5

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部