期刊文献+

超超临界机组的两种典型协调控制方案 被引量:33

Two kinds of typical coordinated control systems in ultra-supercritical units
下载PDF
导出
摘要 目前国内已经投产的1000MW超超临界机组的协调控制系统按照锅炉制造厂的不同分为2种典型的控制方法:煤跟水和水跟煤的协调控制。ALSTOM公司的机组采用水跟煤的协调控制结构,三菱/日立公司的机组采用煤跟水的协调控制结构并辅以动态前馈回路。针对这2种典型控制系统的控制结构进行了分析。现场投运效果表明,这2种结构都能取得良好的控制效果。 The coordinated control systems of 1000 MW ultra-supercritical units in China can be classified as two typical types: coal following water control and water following coal control. ALSTOM used water following coal control structure and HIATCHI/MITSUBISHI used coal following water control structure assisted with dynamic feed forward control. The theory and structure of the two types of coordinated control systems were analyzed. Applications show that both the two types of control systems can get satisfied control performance.
出处 《中国电力》 CSCD 北大核心 2011年第10期74-79,共6页 Electric Power
关键词 超超临界机组 协调控制系统 水煤比 煤跟水控制 水跟煤控制 锅炉输入率需求 ultra-supercritieal unit coordinated control system water fuel ratio coal following water control water following coal control boiler input requirement (BIR)
  • 相关文献

参考文献4

二级参考文献1

共引文献87

同被引文献227

引证文献33

二级引证文献151

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部