期刊文献+

电力谐波和负序监测保护系统的设计 被引量:1

Design of Monitoring and Protection System Based on Power Harmonics and Negative Sequence Current
下载PDF
导出
摘要 为满足国家和供电部门对谐波和负序电流的限制要求,从保证磷基内部供电系统的安全和改善磷基供电的电能质量角度出发,配合总降的功率因数补偿和谐波滤波装置,设计了一种针对磷炉运行过程中产生的谐波和负序电流特性的监测保护系统。通过数据采集站完成对磷炉谐波和负序电流的采集、分析,并通过网络将分析结果传送到总降监视操作站,以达到对电力谐波和负序的监测并实现对系统的保护。 With the limit requirements of harmonic and negative sequence current of national and electricity sector,as well as the security and quality of the phosphorus-based internal power supply system,the monitoring and protection system was designed to detect power harmonic and negative sequence current produced in process of phosphorus furnace operation using harmonic filtering to match the overall drop in power factor compensation.The data of harmonic and negative sequence current was collected and analyzed by the data acquisition station,and results of the analysis were transmitted through the network to the head monitor and operation station of overall drop.By the data,the monitoring and protection system can monitor power harmonic and negative sequence current and protect power supply system.
作者 张令通
出处 《大理学院学报(综合版)》 CAS 2011年第4期35-37,47,共4页 Journal of Dali University
基金 大理学院科研基金资助项目(2007X44)
关键词 谐波 负序 检测 保护 harmonic negative sequence current monitor protection
  • 相关文献

参考文献12

二级参考文献72

共引文献61

同被引文献6

引证文献1

二级引证文献1