期刊文献+

CT系统目测分辨率与系统调制传递函数相关性分析 被引量:7

Correlation Analysis for Modulation Transfer Function and Visual Resolution of CT System
下载PDF
导出
摘要 目的对CT系统MTF(调制传递函数)和目测分辨率之间的关系进行研究。方法扫描CT测试体模中分辨率测试模块,获得系统MTF和目测空间分辨率。结果当MTF为10%时所对应的空间频率与清晰分辨的线对卡分辨率一致,当MTF为2%-5%时对应的空间频率与目测极限分辨率接近。结论通过CT系统MTF和目测分辨率相关关系研究,可以客观反映系统对细节识别能力与人眼识别能力之间的对应关系,从而提高CT质量控制水平。 Objective To evaluate the correlation between the visual resolution and the modulation transfer function(MTF) of CT system.Methods scanned the resolution test module in CT test phantom,obtained the MTF and visual resolution of CT system.Results the resolution which human eyes can clearly distinguish corresponds to spatial frequencies where MTF is 10%;the visual limited resolution corresponds roughly to spatial frequencies where MTF is between 5% and 2%.Conclusion The correlation analysis for MTF and visual resolution of CT can effectively reflect relationship between the true detectability of CT system and human visual acuity and help to raise the level of our work.
作者 白玫
出处 《中国医疗设备》 2011年第4期11-13,共3页 China Medical Devices
基金 国家自然科学基金项目(30870751) 北京市卫生系统高层次卫生技术人才培养计划项目(2009-3-57)
关键词 调制传递函数 目测分辨率 体层摄影术 CT CR modulation transfer function visual resolution tomography CT CR
  • 相关文献

参考文献8

  • 1刘彬,费晓璐,魏岚,白玫.神经介入放射学患者角度对照剂量归一化矩阵[J].中国医疗设备,2008,23(9):1-2. 被引量:1
  • 2白玫,彭明辰.X线CT成像质量评估中的调制传递函数的测试与分析[J].医疗设备信息,2006,21(5):11-13. 被引量:15
  • 3Goodenough D,Atkins F,Dyer S.Automated techniques for quality assurance of radiological image modalities. Image Capture,Formatting,and Display . 1991 被引量:1
  • 4Cunningham IA,Reid BK.Signal and noise inmodulation transfer function determinations usingthe slit,wire,and edge techniques. Medical Physics . 1992 被引量:1
  • 5Droege RT,Morin RL.A practical method to measure the MTF of CT scanners. Medical Physics . 1982 被引量:1
  • 6Fujita H,Tsai D Y,Itoh T,et al.A simple method for determining the modulation transfer function in digital radiography. IEEE Transactions on Medical Imaging . 1992 被引量:1
  • 7Samei E,Flynn M J,Reimann D A.A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Medical Physics . 1998 被引量:1
  • 8Goodenough D,Atkins F.Theoretical and practical aspects of automated quality assurance approaches, particularly for CT. Proceedings of the ICR 89 . 1990 被引量:1

二级参考文献13

  • 1刘彬,白玫,彭明辰.介入诊疗过程中的确定性效应监控方法[J].医疗设备信息,2006,21(2):25-27. 被引量:9
  • 2[1]International Cornmission on Radiological Protection.Avoidance of radiation injuries from medical interventional procedures[J].IcRP Publication 85.Ann ICRP 2000,30:7-67. 被引量:1
  • 3[3]Xu X G,Chao T C,and Bozkurt A.VIP-Man:An image-based whole-boay adult male model constructed from color photographs of the visible human project for multi-particl[J]Monte calculations Health Physics2000,78(5):476-486. 被引量:1
  • 4[4]A.Servomaa and M.Tapiovaara.Organ dose calculation in medical X ray examinations by the program PCXMC[J].Radiation Protection Dosimetry.1998.80:213-219. 被引量:1
  • 5[6]DOuglas W.Fletcher,Donal L.Miller,Stephen Balter.Comparison of Four Techniques to Estimate Radiation Dose to Skin Duritng Angiographic and Interventional Radiology Procedures[J].Vas Interv Radiol,2002,13:391-397. 被引量:1
  • 6Goodenough D,Atkins F,Dyer S.Automated techniques for quality assurance of radiological image modalities.SPIE.Image Capture,Formatting,and Display,1991,1444:87-99. 被引量:1
  • 7Dainty JC,Shaw R.Image Science[M].New York:Academic Press,1974. 被引量:1
  • 8Goodenough D,Atkins F.Theoretical and practical aspects of automated quality assurance approaches,particularly for CT[C].Proceedings of the ICR 89,editors Silve,et.Al,1990. 被引量:1
  • 9Fujita H,Tsai D-Y,Itoh T,et al.A simple method for determining the modulation transfer function in digital radiography[J].IEEE Transactions on Medical Imaging,1992,11:34-39. 被引量:1
  • 10Cunningham IA,Reid BK.Signal and noise in modulation transfer function determinations using the slit,wire,and edge techniques[J].Medical Physics,1992,19:1037-1044. 被引量:1