摘要
目的:通过对石墨炉原子吸收光谱法测定尿铅含量影响因素的研究,找出解决办法。方法:采用标准加入法;控制空白管的吸光度;对石墨炉升温参数进行合理的选择;使用热解凃层石墨管;选择合适的基体改进剂及选择合适加入量。结果:精密度试验、回收率试验与标准质控尿样测定都符合要求,标准曲线在0μg/L^80μg/L范围内线性良好,平均回归方程为:Y=0.00113C-0.0052,相关系数r=0.99935,方法检出限为7.42μg/L,能满足铅吸收和铅中毒职业病诊断的要求。结论:使用石墨炉原子吸收光谱法测定尿铅,操作简单、快速、回收率高、背景干扰少、结果准确可靠,适合用于职业接触人群中大样本尿铅的测定。
Objective:Graphite furnace atomic absorption spectrometry determination of lead content in urine of factors,to find a solution.Methods: The standard addition method;control of the absorbance of the blank tube;parameters of graphite furnace heating a reasonable choice;use of pyrolytic coated graphite tube;choose a suitable matrix modifier agent and select the appropriate dosage.Results: The precision of the recovery test and the standard quality control urine samples were determined to meet the requirements of the standard curve in the 0 μg/L^80 μg/L was well inside the range,the average regression equation: Y=0.00113C-0.0052,correlation coefficient r=0.99935.The detection limit was 7.42 μg/L,to meet the diagnosis of occupational lead absorption and lead poisoning requirements.Conclusion: The use of graphite furnace atomic absorption spectrometry determination of lead in urine,simple,fast,high recovery rate and less background interference,accurate and which can be high,suitable for a large sample population occupational exposure to the determination of lead in urine.
出处
《中国卫生检验杂志》
CAS
2011年第2期331-332,共2页
Chinese Journal of Health Laboratory Technology
关键词
石墨炉原子吸收光谱法
尿铅
影响因素
研究
Graphite furnace atomic absorption spectrometry
Urinary lead
Factors
Research