摘要 按不同设防烈度设计10层框架-剪力墙结构,计算了不同设防烈度下的建筑工程造价。对比可知,设防烈度8度以下,设防水准提高一个等级,建筑工程造价增加比例小于6.97%,增加成本占房屋售价的比例小于0.852%。框架-剪力墙结构建筑工程造价较小的增加,可获得设防水准一个等级的提高。从另一个角度说,在减少建筑面积很小的情况下,房屋的抗震设防水准可获得一个等级的提高。 The 10-layer typical frame-shear wall structure of different protect intensity are designed.The construction cost is calculated.When the protect intensity is smaller than 8 degree,the increased construction cost would be smaller than 6.97% and the increased construction cost is smaller than 0.852% of its price if the protect standard raises 1 level.The construction cost has a little increase,the protect standard would raise 1 level.In other words,if the construction cost doesn't increase,the protect standard would also raise 1 level when the architectural area decreases very small.
作者 韩淼 李守静
出处 《工程抗震与加固改造》 北大核心 2010年第6期132-136,共5页 Earthquake Resistant Engineering and Retrofitting
基金 地震行业科研专项项目(200808009) 国家科技支撑计划课题(2006BAC13B01-0601)
关键词 设防烈度 框架-剪力墙结构 建筑工程 工程造价 protect intensity frame-shear wall structure building engineering construction cost