摘要 介绍铝芯电缆使用后,电缆连接时的接管连接方式、不同连接方式对产品性能的影响,试验证明了铝接管连接铝芯电缆、镀锡铜接管连接铝芯电缆、铜铝过渡接管分别连接铜铝电缆的可行性,并指出导体连接应该注意的问题。 The nozzle connection methods of cable connection and the influences of different connection methods on the products performance after using the aluminum core cable were presented.The tests indicated that the feasibility of using the aluminum nozzle to connect the aluminum core cables,the tin plating copper nozzle to connect the aluminum core cables,and the copper and aluminum excessive nozzle respectively to connect the copper and aluminum cables.The problems needed to pay attention on in the conductor connection method were also pointed out.
出处 《华东电力》 北大核心 2010年第10期1629-1631,共3页 East China Electric Power
关键词 铝芯电缆 连接方式 压接试验 aluminum core cable connection method crimping experience
  • 相关文献

参考文献3

二级参考文献13

  • 1淮平,程奇松.铜包铝芯市内通信电缆的设计与制造[J].电线电缆,2007(2):19-22. 被引量:4
  • 2黄崇祺.金属导体及其应用[M].上海电缆研究所,2007. 被引量:3
  • 3王恭敏.国内外铝工业发展状况和我国铝工业政策[A].2007年上海铜铝峰会——资源、价格与市场文集[C].2007.22-36. 被引量:1
  • 4常州市武进恒通金属钢丝有限公司.铜包钢芯铜包铝绞线鉴定文件[Z].2007. 被引量:1
  • 5GB/T12706-2002额定电压lkV到35kV挤包绝缘电力电缆及附件. 被引量:1
  • 6GB/T3956-21997电缆的导体. 被引量:1
  • 7GB/T 3048-21994电线电缆电性能试验方法-导体直流电阻试验. 被引量:1
  • 8GB14315—21993电力电缆导体用压接型铜、铝接线端子和连接管. 被引量:1
  • 9GB50303-22002建筑电气工程施工质量验收规范. 被引量:1
  • 10尹燕著.节降损耗之我见.电线电缆报.上海:上海电缆研究所.2004. 被引量:1

共引文献26

同被引文献32

  • 1徐英.压接连接工艺技术研究[J].电子工艺技术,2005,26(1):21-23. 被引量:27
  • 2张德铭,梁明,王生明,马蓉,顾欢欢.新型电力电缆接头故障监测系统的设计[J].电气应用,2005,24(1):29-31. 被引量:13
  • 3张金专,刘珠峰,李旭航.过负荷情况下插头插座升温情况研究[J].消防技术与产品信息,2007,20(3):44-46. 被引量:6
  • 4GB/T14315--2008,电力电缆导体用压接型铜、铝接线端子和连接管[S]. 被引量:2
  • 5IEC 60287-2-1 : 1994, Calculation of the Current Rating of E- lectric Cables, Part 2: Thermal Resistance, Section 1. Cal- culation of Thermal Resistanee[S]. 被引量:1
  • 6BHATTACHARYYA S, CHOUDHURY A, JARIWALA H. Electrical Performance of Conductive Bolted Joints of Cop- per and Aluminum Conductors[J]. Int J Engg Techsci, 2011, 2(4) : 275-280. 被引量:1
  • 7BRAUNOVIC M. Effect of Connection Design on The Con- tact Resistance of High Power Overlapping Bolted Joints[J]. IEEE Transactions on Components and Packaging Technolo- gies, 2002, 25(4): 642-650. 被引量:1
  • 8BRAUNOVIC M. Reliability of Power Connections [J]. Journal of Zhejiang University SCIENCE A, 2007, 8 (3) 343-356. 被引量:1
  • 9BERGMANN R. Model to Assess the Reliability of Electrical Joints[C]//Proceedings of the Forty-second IEEE HOLM Conference on Electrical Contacts. Chicago, America: IEEE, 1996: 180-188. 被引量:1
  • 10SCHOFT S. Joint Resistance Depending on Joint Force of High Current Aluminum Joints [C]//Proceedings of the 22nd Conference on Electrical Contacts. Seattle, America: IEEE, 2004: 502-510. 被引量:1

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部