期刊文献+

RLG环形激光陀螺测试技术的研究与设计 被引量:4

The Research and Design of Ring Laser Gyro Testing Technology
下载PDF
导出
摘要 采用Allan方差法对环形激光陀螺(Ring Laser Gyro)传感器的输出特性进行了分析,完成了对RLG频域输出误差的建模评估,包括零偏稳定性、随机游走以及马尔可夫噪声等,并根据评估分析建立了温度误差零偏补偿模型;同时,在测试系统设计中,使用了转台交差逆转法,尝试将零偏稳定性中的常值漂移和线性漂移部分自动补消,结果表明可以改善传统的RLG转台测试法的单一测量功能及精度。 On the basis of Ring Laser Gyro's output error characteristic,adopted Allan variance to analyze global error of RLG,and completed modeling evaluation in frequency domains of RLG which including bias stability,random walk and Markov random yawping,etc.Set up bias compensation model because of temperature which base on Allan variance evaluation result of RLG errors.Using of Allan variance method can correct output error of RLG in frequency-domain from time-domain.Attempted to compensate constant excursion and linearity excursion of bias stability by method of Interleaving-Athwart turntable testing which can advance measure precision of RLG turntable testing by tradition method effectually.
出处 《传感技术学报》 CAS CSCD 北大核心 2010年第10期1435-1438,共4页 Chinese Journal of Sensors and Actuators
基金 军内科研资助
关键词 环形激光陀螺 陀螺测试 Allan方差法 温度补偿 零偏稳定性分析 ring laser gyro(RLG) gyroscope testing allan variance temperature compensation bias instability analysis
  • 相关文献

参考文献10

二级参考文献44

共引文献89

同被引文献31

  • 1王淑娟,吴广玉.惯性器件温度误差补偿方法综述[J].中国惯性技术学报,1998,6(3):44-49. 被引量:32
  • 2张鹏飞,龙兴武,汤建勋,王宇,李革,许光明.机抖激光陀螺的零偏的实时温度补偿方法研究[J].传感技术学报,2007,20(6):1279-1282. 被引量:3
  • 3Chokovani V, Umakhanov I O, Marusyk P I. The Compensated Differential CVG [ C ]//Symposium Gyro Technology, Karlsruhe, Germany,2008.3.1-3.8. 被引量:1
  • 4Yi Tao, Xuezhong Wu, Dingbang Xiao, et al. A Novel Cupped Solid-State Wave Gyroscope [ C ]//Proceding of 2010 International Conference on Mechanical and Aerospace Engineering. Malaysia: IEEE ,2010:449-453. 被引量:1
  • 5Chikovani V V, Okon I M, Barabashov A S. A Set of High Accuracy Low Cost Metallic Resonator CVG [ C ]//Proceedings of the IEEE/ ION Position, Location And Navigation Symposium, Monterey, USA, 2008:238-243. 被引量:1
  • 6Watson W. Vibrating Structure Gyro Performance Improvements [ C ]//Symposium Gyro Technology, Stuttgart, Germany,2008:6.0 -6.13. 被引量:1
  • 7Shu-Chung Yi. A Direct Digital Frequency Synthesizer Based on ROM Free Algorithm [ J ]. Int. J. Electron. Commun. , 2010,64 : 1068-1072. 被引量:1
  • 8TAO Yi, XI Xiang, XIAO Dingbang. Design, Analysis and Experiment of a Novel Ring Vibratory Gyroscope [ J ]. CHINESE Sensors and Actuators A : Physical. 2011,168:286-299. 被引量:1
  • 9Yawgeng A Chau,Yao-Hua Chen. A High-Performance ROM-Less Direct Digital Frequency Synthesizer [ J ]. Int. J. Electron. Commun. ,2011,65:272-274. 被引量:1
  • 10Amir M,Sodagar G,Roientan L,et al. Reduced Memory Direct Digital Frequency Synthesizer Using Parabolic Initial Guess [ J ]. Analog Integrated Circuits and Signal Processing,2003 ,M:89-96. 被引量:1

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;