分析了某炼油厂硫冷凝器换热管与管板连接接头失效的原因,根据分析结果对其结构进行了相应改进。
In allusion to joints' failure of the sulpher condenser's tubes and tube-sheets in a refinery,the causes was analyzed and solved in structural design accordingly.As a result,good effect was obtained after reconstruction.
出处
《石油化工设备》
CAS
2010年第B08期70-72,共3页
Petro-Chemical Equipment
关键词
冷凝器
换热管
管板
结构
condenser
tube
tube-sheet
structural