期刊文献+

Pharmacokinetic Monitoring of Indocyanine Green for Tumor Detection Using Photoacoustic Imaging 被引量:6

Pharmacokinetic Monitoring of Indocyanine Green for Tumor Detection Using Photoacoustic Imaging
下载PDF
导出
摘要 We report tumor detection using a photoacoustic technique for the imaging of angiogenesis and monitoring of agent pharmacokinetics on an animal model. We take 532-nm laser pulses to excite photoacoustic signals of blood vessels with acquisition by a broadband hydrophone, and the morphological characteristics of tumor angiogenesis are successfully image depicted. Furthermore, tumor pharmacokinetics is preformed and analyzed with fast multielement photoacoustic imaging of the intravenous-injected indocyanine green (ICG). Photoacoustic signals of ICG are excited with 805 nm laser pulses and recorded by transducer array as a function of time. The difference between the photoacoustic signal from the tumor side and that from the normal side is observed, and the ICG clearance velocity in the tumor area is found to lag behind that in the normal area. Experimental results demonstrate that photoacoustie imaging of morphological parameter and pharmacokinetics with specific agent may provide high sensitive approach for tumor detection and localization. We report tumor detection using a photoacoustic technique for the imaging of angiogenesis and monitoring of agent pharmacokinetics on an animal model. We take 532-nm laser pulses to excite photoacoustic signals of blood vessels with acquisition by a broadband hydrophone, and the morphological characteristics of tumor angiogenesis are successfully image depicted. Furthermore, tumor pharmacokinetics is preformed and analyzed with fast multielement photoacoustic imaging of the intravenous-injected indocyanine green (ICG). Photoacoustic signals of ICG are excited with 805 nm laser pulses and recorded by transducer array as a function of time. The difference between the photoacoustic signal from the tumor side and that from the normal side is observed, and the ICG clearance velocity in the tumor area is found to lag behind that in the normal area. Experimental results demonstrate that photoacoustie imaging of morphological parameter and pharmacokinetics with specific agent may provide high sensitive approach for tumor detection and localization.
出处 《Chinese Physics Letters》 SCIE CAS CSCD 2010年第9期123-126,共4页 中国物理快报(英文版)
基金 Supported by the National Basic Research Program of China (2010CB732602), the Program for Changjiang Scholars and Innovative Research Team in University (IRT0829), the National Natural Science Foundation of China under Grant Nos 30627003 and 30870676, and the Natural Science Foundation of Guangdong Province (7117865).
  • 相关文献

参考文献14

  • 1Razansky D, Distel M, Vinegoni C, Ma R, Perrimon N, Kvster R W and Ntziachristos V 2009 Nature Photon. 3 412. 被引量:1
  • 2Zhang H F, Stoica M G and Wang L H 2006 Nature Biotechnol. 24 848. 被引量:1
  • 3Yang D W, Xing D, Yang S H and Xiang L Z 2007 Opt. Express 15 15566. 被引量:1
  • 4Chen X, Tang Z L, He Y H, Liu H F, Wei Y D and Wu Y B 2009 J. Biomed. Opt. 14 059801. 被引量:1
  • 5Su Y X, Zhang F, Xu K X, Yao J Q and Wang R K 2005 J. Phys. D: Appl. Phys. 38 2640. 被引量:1
  • 6Yang S H, Xing D, Zhou Q, Xiang L Z and Lao Y Q 2007 Med. Phys. 34 3294. 被引量:1
  • 7Yang S H, Xing D, Lao Y Q, Yang D W, Zeng L M, Xiang L Z and Chen W 2007 Appl. Phys. Lett. 90 243902. 被引量:1
  • 8Lao Y Q, Xing D, Yang S H and Xiang L Z 2008 Phys. Med. Biol. 53 4203. 被引量:1
  • 9Xiang L Z, Xing D, Gu H M, Zhou F F, Ying D W, Zeng L M and Yang S H 2007 Chin. Phys. Lett. 24 751. 被引量:1
  • 10Hawrys D and Sevick-Muraca E 2000 Neoplasia 2 388. 被引量:1

同被引文献31

  • 1沈瑞琪,孙同举,戴实之.1.06μm激光作用下硅解离的光声谱[J].应用激光,1995,15(6):253-254. 被引量:4
  • 2Yang Xinmai, Anastasios Maurudis, John Gamelin, et al. Photoacoustic tomography of small animal brain with a curved array transducer [J]. Journal of Biomedical Optics, 2009, 14 (5) : 0540071-0540075. 被引量:1
  • 3Li Menglin, Oh Jung Taek, Xie Xueyi, et al. Simultane- ous molecular and hypoxia imaging of brain tumors in vivo using spectroscopic photoacoustic tomogra- phy [J].Proceedings of the IEEE, 2008,96 (3): 481-489. 被引量:1
  • 4Wei Yadong, Tang Zhilie, Zhang Hanchao, et al.Photoacoustic tomography imaging using a 4f acoustic lens and peak-hold technology [J]. Optics Express, 2008, 16 (8) : 5314-5319. 被引量:1
  • 5Yang Diwu, Xing Da, Tan Yi, et al. Integrative prototype B-scan photoacoustic tomography system based on a novel hybridized scanning head [J]. Applied Physics Letter, 2006, 88 (17) : 174101-174103. 被引量:1
  • 6Tao Chao, Liu Xiaojun. Reconstruction of high quality photoacoustic tomography with a limited-view scanning [J]. Optics Express, 2010, 18 (3) : 2760-2766. 被引量:1
  • 7Zhang Chi, Wang Yuanyuan. Deconvolution Reconstruc- tion of Full-view and Limited-view Photoacoustic To- mography: a Simulation Study [J]. Journal of the Optical Society of America A, 2008,25 (10) : 2436-2443. 被引量:1
  • 8Wang Yi,Xing Da,Zeng Yaguang,et al.Photoacoustic imaging with deconvolution algorithm [J].Phys. Med. Biol., 2004, 49 (14) : 3117-3124. 被引量:1
  • 9Xu Minghua, Wang Lihong. Time-domain reconstruction for thermoacoustic t6mography in a spherical geometry [J]. IEEE Trans. Med. Imaging, 2002,21 (7) : 814-822. 被引量:1
  • 10TAO CHAO,LIU XIAOJUN. Reconstruction of highquality photoacoustic tomography with a limited-view scanning [J]. Optics express, 2010, 18 (3) : 2760-2766. 被引量:1

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部