期刊文献+

戴用劳动保护眼镜后角膜异物的临床分析 被引量:2

Clinical analysis of corneal foreign body after wearing protective spectacles
下载PDF
导出
摘要 目的了解戴用劳动保护眼镜后角膜异物的发生情况。方法收集2008年7月至2009年6月在我院就诊的146例(146眼)角膜异物患者,根据其受伤时有无戴用劳动保护眼镜将其分为戴镜组和未戴镜组,对患者的一般资料及角膜异物的大小、位置等进行收集,并进行统计学分析。结果 2组患者年龄、病程、矫正视力等差异均无统计学意义,而未戴镜组患者的文化程度偏低,与戴镜组相比差异有统计学意义(P<0.05)。戴镜组角膜异物直径为(0.46±0.06)mm,未戴镜组角膜异物直径为(0.57±0.08)mm,2者间差异亦有统计学意义(P<0.05)。戴镜组角膜颞下区(28眼,48.28%)和中央区(16眼,27.59%)异物为多见,鼻下区(12眼,20.69%)次之,最少为鼻上区(2眼,3.45%)及颞上区(0眼)。未戴镜组角膜鼻下区(44眼,50.00%)、颞下区(24眼,27.27%)和中央区(18眼,20.45%)异物多见,颞上区(2眼,2.27%)及鼻上区(0眼)少见。戴镜组和未戴镜组角膜异物在鼻下区的分布百分数差异有统计学意义(P<0.05),余各分区差异均无统计学意义(均为P>0.05)。结论戴用劳动保护眼镜能有效防止异物的进入,但劳动保护眼镜颞下方与面部间有缝隙,异物可从此进入,建议设计时加强颞下方防护。 Objective To investigate the incidence of corneal foreign body after wearing protective spectacles.Methods A total of 146 cases(146 eyes) with corneal foreign body were recruited in our hospital between July 2008 and June 2009.Cases were divided into 2 groups,groups with or without protective spectacles groups.Common data of cases,location and size of foreign bodies were collected and statistically analyzed.Results There was no statistical difference in age,course and corrected visual acuity between the two groups,but the culture degree of group without spectacles was lower than group with spectacles,there was statistical difference(P0.05).The diameters of foreign body were (0.46±0.06)mm and (0.57±0.08)mm in group with spectacles and group without spectacles,respectively,and there was statistical difference between the two groups(P0.05).In group with spectacles,inferotemporal side (28 eyes,48.28%)of cornea was the most common position with foreign body,followed by central side(16 eyes,27.59%),inferonasal side(12 eyes,20.69%),superonasal side(2 eyes,3.45%)and superotemporal side(0 eye).In group without spectacles,inferonasal side(44 eyes,50.00%) of cornea was the most common position with foreign body,followed by inferotemporal side(24 eyes,27.27%),central side(18 eyes,20.45%),superotemporal side(2 eyes,2.27%),superonasal side(0 eye).The percent of foreign body location on inferonasal side was significantly different between the two groups(P0.05),but no difference was found in other sides between the two groups(all P0.05).Conclusions Protective spectacles can effectively prevent foreign body,but foreign body can enter eyes through the gap below inferotemporal side.More improvement needs to be done in design for protecting the inferotemporal side.
出处 《眼科新进展》 CAS 北大核心 2010年第6期565-566,569,共3页 Recent Advances in Ophthalmology
关键词 劳动保护眼镜 角膜异物 角膜颞下区 protective spectacles corneal foreign body corneal inferotemporal side
  • 相关文献

参考文献7

二级参考文献39

共引文献52

同被引文献26

  • 1罗蓉.儿童眼外伤168例分析报告[J].眼外伤职业眼病杂志,2005,27(10):780-781. 被引量:21
  • 2周恩林,彭穗英.金属性角膜异物的剔出物细菌培养分析[J].眼外伤职业眼病杂志,2006,28(12):947-948. 被引量:15
  • 3刘祖国.眼表疾病学[M].北京:人民卫生出版社,2004:613. 被引量:26
  • 4刘家琦.实用眼科学[M].第2版.北京:人民卫生出版社,2005.34-35. 被引量:25
  • 5赵堪兴.眼科学[M].第8版,北京:人民卫生出版社,2013,176. 被引量:25
  • 6Ramakrishnan T,Constantinou M,Jhanji V,et al. Corneal metallic foreign body injuries due to suboptimal ocular protection[J]. Arch Environ Occup Health,2012,67 (1): 48-50. 被引量:1
  • 7Ashley B,Zale M,Stephanie Br. Evaluating the need for close follow-up after removal of a noncomplieated corneal foreign body[J]. Cornea, 2014,33 ( 11 ) : 1193-1196. 被引量:1
  • 8I Woo JH,Sundar G. Eye injuries in Singapore,don't risk it,do more a prospective study[J]. Ann Acad Med Singapore, 2006,35(10) :706-718. 被引量:1
  • 9Macedo Filho ET,Lago A,Duarte K,et al. Super cial corneal foreign body:Laboratory and epidemiologic aspects[J]. Arq Bras Oftalmol, 2005,68 : 821-823. 被引量:1
  • 10DeBroff BM, Donahue SP, Caputo B J, et al. Clinical char- acteristics of corneal foreign bodies and theirassociated culture results[J]. CLAO J, 1994,20:128-130. 被引量:1