期刊文献+

前列腺癌调强计划改变多叶准直器角度对直肠和膀胱剂量的影响 被引量:6

The Impact of Change Angle of Multi-leaf Collimator on the Dose Distribution of the Intensity-modulated Radiation Therapy Plan for Prostate Cancer
下载PDF
导出
摘要 目的:常规放疗的前列腺癌,由于直肠和膀胱的剂量限制,治疗结束后活检阳性率较多。剂量递增实验证明,高剂量照射能提高前列腺癌的局部控制率和生存率。本文以前列腺癌为例,在保证肿瘤区域剂量的前提下,探讨调强计划中改变多叶准直器角度对减少直肠和膀胱剂量的影响。材料方法:选取10例已放疗患者的CT作为研究对象,用调强技术比较改变多叶准直器角度对直肠和膀胱的剂量影响。结果:直肠的D25、D50、V60和膀胱的D30、D50、V60在改变多叶准直器角度后都有明显减少。结论:在前列腺癌靶区复杂,且计划因肿瘤剂量和正常组织剂量不能同时满足时,应用此方法可以一定程度上减少正常组织的受照剂量。 purpose: Common radiation therapy for prostate cancer, positive rate were more after treatment due to the rectum and bladder dose limit. Dose escalation experiments show that high doses of radiation can improve local control of prostate cancer rate and survival rate. In this paper, in ensuring the dose of tumor, explores the impact of change angle of multi-leaf collimator on the dose distribution of the intensity-modulated radiation therapy plan for prostate cancer. Material Methods: Select 10 eases had radiotherapy patient's CT as an object of study, compared with the impact of change angle of multi-leaf collimator on the dose distribution of the intensity-modulated radiation therapy plan for prostate cancer. Results: The rectum D25,D50, V60 and bladder D30、D50, V60 all decreased significantly after changed the angle of multi-leaf collimator. Condusion: The application of this method can to some extent reduce the dose to normal tissue for complex target volume plans when plans fail to satisfy the tumor dose and normal tissue simultaneously.
出处 《中国医学物理学杂志》 CSCD 2010年第3期1844-1847,共4页 Chinese Journal of Medical Physics
关键词 前列腺癌 放射治疗 逆向调强放疗计划 多叶准直器的角度 直肠和膀胱剂量 prostate cancer radiation therapy reverse intensity-modulated radiation therapy plan angle of multi-leaf collimator dose of rectum and bladder
  • 相关文献

参考文献14

  • 1Lo Sasso T,Chui CS,Katcher GJ,et al.The use of multi -leaf collimators for conformal radiotherapy of carcinomas of prostate and nasophrynx[J].Int J Radiat Oncol Biol Phys,1993;25 (2):161. 被引量:1
  • 2Brahme A.Optimal setting of multi-leaf collimators in stationary beam radiation therapy[J].Strahlenther.Onkol,1988;164(6):343. 被引量:1
  • 3Yu CX,Yan D,Du MN,et al.Optimization of leaf position when shaping a radiation field with a multi-leaf collimator[J].Phys Med Biol,1995;40 (2):305. 被引量:1
  • 4徐利明,何正中,王晓红.MLC不规则野射野边缘的剂量符合度研究[J].中国医学物理学杂志,2004,21(1):9-12. 被引量:7
  • 5ICRU.Prescribing,Recording and Reporting Photom Beam Therapy (Supplement to ICRU Report 50)[S].ICRU Report No.62,1999:12. 被引量:1
  • 6Julie Chapek,Matt Tobler,Beau J.Toy,et al.Optimization of Collimator Parameters to Reduce Rectal Dose in Intensity-Modulated Prostate Treatment Planning[J].Medical Dosimetry,2005;30(4):205-212. 被引量:1
  • 7Gert O,Luc A,Werner RT,et al.Robert AP,Gerald EH,Shawn WM,et al.Radiotherapy of Prostate Cancer with or without Intensity Modulated Beams:a Planning Comparison[J].Int J Radiat Oncol Biol Phys,2000;47:639-648. 被引量:1
  • 8Zelefsky MJ,Leibel SA,Kutcher GJ,et al.Three -dimensional conformal radiotherapy and dose escalation:where do we stand?[J].Semin Radiat Oncol,1998;8:107-114. 被引量:1
  • 9Zelefsky MJ,Leibel SA,Gaudin PB,et al.Dose escalation with three dimensional conformal radiation therapy affects the outcome in prostate cancer[J].Int J Radiat Oncol Biol Phys,1998;41:491-500. 被引量:1
  • 10Boersma LJ,van den Brink M,Bruce AM,et al.Estimation of the incidence of late bladder and rectum complications after high-dose (70-78 Gy) conformal radiotherapy for prostate cancer,using dose volume histograms[J].Int J Radiat Oncol Biol Phys,1998;41:83-92. 被引量:1