摘要
采用电导法对新型低温电解质体系的分子比进行测定,提出了系统的测量方法、计算公式及修正方案。通过对标准电解质和真实电解槽中电解质试样分子比的测定,证明了该方法适应于新型的KF-AlF3-Al2O3-X低温电解质体系,分析结果与国家质检中心的化学成分分析法相对比,结果一致。
Conductance method was applied to determine the molar ratio in the new low - temperature electrolyte system. The systematic measurement method, calculation formula and modified program were proposed, The molar ratio determination of standard electrolyte and eJectrolyte samples from lab electrolytic: cell proved that the method can be adapted to the new KF - AlF3 - Al2O3 - X low - temperature electrolyte system and the results were in agreement with those by the chemical composition analysis of the National Quality Supervision and Test Center.
出处
《轻金属》
CSCD
北大核心
2010年第3期25-29,共5页
Light Metals
关键词
分子比
电导法
低温电解质
molar ratio
conductance method
low - temperature electrolyte