期刊文献+

积极推进胸部低剂量CT扫描的临床应用 被引量:81

原文传递
导出
摘要 胸部组织的天然高对比使胸部CT低剂量扫描成为目前最广泛的应用领域;随着MSCT的发展,其应用范围从最早的筛查,到呼吸道三维成像、儿童检查、胸部CT血管造影以及经皮穿刺引导等一再得以拓宽。如何正确对待和合理使用是目前的热点。
作者 刘士远 于红
出处 《中华放射学杂志》 CAS CSCD 北大核心 2010年第1期6-7,共2页 Chinese Journal of Radiology
  • 相关文献

参考文献10

  • 1Kim MJ, Park CH, Choi SJ, et al. Muhidetector computed tomography chest examinations with low-kilovohage protocols in adults: effect on image quality and radiation dose. J Comput Assist Tomogr,2009 ,33 :416-421. 被引量:1
  • 2Nitta N, Takahashi H, Murata K, et al. Ultra low dose helical CT of the chest: evaluation in clinical cases. Radiat Med, 1999, 17: 1-7. 被引量:1
  • 3张军,肖湘生,刘士远,陶晓峰,于红,李惠民.16层CT肺部筛查低剂量技术研究[J].中国医学计算机成像杂志,2006,12(3):175-178. 被引量:30
  • 4Lopes Pegna A, Picozzi G. Lung cancer screening update. Curr Opin Pulm Med,2009, 15:327-333. 被引量:1
  • 5Plurad D, Green D, Demetriades D, et al. The increasing use of chest computed tomography for trauma: is it being overutilized? J Trauma,2007,62:631-635. 被引量:1
  • 6Hatayama O, Kobayashi T, Fujimoto K, et al. Utility of single- slice high-resolution CT in upper lung field combined with low- dose spiral CT for lung-cancer screening in the detection of emphysema. Intern Ned ,2007,46 : 1519-1525. 被引量:1
  • 7彭芸,马大庆,李剑颖,张祺丰,刘玥,王蓓,曾津津.64层螺旋CT自动管电流调节技术在婴幼儿胸部低剂量CT扫描中应用的可行性研究[J].中华放射学杂志,2008,42(10):1045-1049. 被引量:40
  • 8Orlandi I, Moroni C, Camiciottoli G, et al. Spirometric-gated computed tomography quantitative evaluation of lung emphysema in chronic obstructive pulmonary disease : a comparison of 3 techniques, J Comput Assist Tomogr,2004,28: 437-442. 被引量:1
  • 9周旭辉,彭振鹏,郑丽丽,李树荣,杨智云,孟悛非,陈星.64层螺旋CT肺动脉成像低管电压设置结合个体化对比剂应用的对照研究[J].中华放射学杂志,2009,43(7):704-707. 被引量:48
  • 10Heyer CM, Kagel T, Lemburg SP, et al. Transbronchial biopsy guided by low-dose MDCT: a new approach for assessment of solitary pulmonary nodules. AJR,2005 , 187:933-939. 被引量:1

二级参考文献33

  • 1Colang JE, Killion JB, Vano E. Patient dose from CT: a literature review. Radiol Technol, 2007,79 : 17-26. 被引量:1
  • 2Brenner, DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med, 2007, 357: 2277 -2284. 被引量:1
  • 3Brody AS, Frush DP, Huda W, et al. Radiation risk to children from computed tomography. Pediatrics ,2007,120:677-682. 被引量:1
  • 4Kalra MK, Rizzo S,Maher MM,et all Chest CT performed with Z-axis modulation : scanning protocol and radiation dose. Radiology, 2005,237 : 303 -308. 被引量:1
  • 5Namasivayam S, Kalra MK, Pottala KM, et al. Optimization of Z-axis automatic exposure control for multideteetor row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose. AJNR,2006,27: 2221-2225. 被引量:1
  • 6Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients. Radiology,2004, 233 : 241-249. 被引量:1
  • 7Kalra MK, Maher MM, D'Souza RV,et al. Detection of urinary tract stones at low-radiation-dose CT with Z-axis automatic tube current modulation: phantom and clinical studies. Radiology, 2005,235:523-529. 被引量:1
  • 8Naidich DP, Marshall CH, Gribbin C, et al. Low-dose CT of the lungs : preliminary observations. Radiology, 1990,175:729-731. 被引量:1
  • 9Itoh S, Ikeda M, Arahata S, et al. Lung cancer screening: minimum tube current required for helical CT. Radiology, 2000, 215:175-183. 被引量:1
  • 10Schueller-Weidekamm C,Schaefer-Prokop CM,Weber M,et al.CT angiography of pulmonary arteries to detect pulmonary embolism:improvement of vascular enhancement with low kilovoltage settings.Radiology,2006,241:899-907. 被引量:1

共引文献110

同被引文献573

引证文献81

二级引证文献624

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部