摘要
介绍变配电房增容改造中,通过科学计算,研究制订出电力变压器容量、台数选配方案及经济运行问题。根据学院一年的用电特性,采取留用一台原S9型变压器,新增一台S11变压器的配置方案,既能降低电耗,又可节约投资,实现了变压器的经济运行。
The paper does research on power transformer capacity and number selection and economic problems through scientific calculations in the introduction of transformation and distribution room uprating reconstruction. According to the electrical characteristics of the institute in a whole year, the configuration scheme of retaining a former S9 transformer and adopting a new S11 transformer can not only reduce power consumption but also save investments in order to achieve transformer economic operation.
出处
《电力需求侧管理》
2010年第1期57-58,共2页
Power Demand Side Management
关键词
变配电房
节能改造
变压器选配
经济运行
transformation and distribution room
energy-saving transformation
transformer selection
economic operation