摘要 船舶电力主接线的可靠性是关系整个船舶电力系统安全运行的关键。计算电气主接线相关的可靠性指标时需要不交化最小路,本文利用容斥定理的特点,直接对最小路进行不交化,进而计算出船舶电力主接线的可靠性指标。该方法逻辑清晰,易于实现,为某大型船舶中压电力系统的结构设计提供了重要技术支撑。 The reliability of main electrical connection lines is critical to the safety of ship power system. Constructing disjoint minimal pathset is an important approach for reliability analysis of power network. In this article, we apply the admissible and repelling law to disjoint minimal pathset directly. Based on that, the reliability indexs are obtained. This approach is logically and can be simply achieved by computer programming. It is used sucessfully in a large ship power system design.