图像配准技术及其在肿瘤放疗中的应用 被引量:1

原文传递
导出
摘要 图像配准(image registeration,IR)技术作为一种有用的工具,应用于医学图像分析已有20多年历史了。虽然其应用于肿瘤放疗临床历史较短,但其重要性日渐显露。继三维适形放疗和调强放疗后新放疗技术一图像引导放疗的出现,使图像配准技术扮演了重要角色。
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2009年第6期498-500,共3页 Chinese Journal of Radiation Oncology
  • 相关文献

参考文献35

  • 1Crum WR, Hartkens T, Hill DLG. Non-rigid image registration: therapy and practice. Br J Radiol,2004,77:140-153. 被引量:1
  • 2戴建荣,胡逸民.图像引导放疗的实现方式[J].中华放射肿瘤学杂志,2006,15(2):132-135. 被引量:184
  • 3李光明.医学图像的配准//田捷,包尚联,周明全,编著.医学影像处理与分析.北京:电子工业出版社,2003:96. 被引量:2
  • 4Yan D ,Jaffray DA, Wong JW. A model to accumulate fractionated dose in a deforming organ. Int J Radiat Oncol Biol Phys, 1999,44: 665 -675. 被引量:1
  • 5Schaly B,Kempe J, Bauman G, et al. Tracking the dose distribution in radiation therapy by accounting for variable anatomy. Phys Med Biol,2004 ,49 :791-805. 被引量:1
  • 6Dawson LA, Eccles C, Kirilova A, et al. Three dimensional motion of liver tumors using cine MRI compared to liver motion assessed at fluoroscopy. Radiother Oncol,2006, A483 : S214. 被引量:1
  • 7Lu W, Chen M, Olivera G, et al. Fast free-form deformable registration via calculus of variations. Phys Med Biol, 2004,49 : 3067- 3087. 被引量:1
  • 8Sarrut D,Boldea V, Miguet S, et al. Simulation of 4D CT images from deformable registration between inhale and exhale breath-hold CT scans. Med Phys,2006 ,33 :605-617. 被引量:1
  • 9Coselmon M, Baiter J, McShan D, et al. Mutual information based CT registration of the lung at exhale and inhale breathing states using thinplate splines. Med Phys,2004,31:2942-2948. 被引量:1
  • 10Brock K, Baiter J, Dawson L, et al. Automated generation of a four- dimensional model of the liver using warping and mutual information. Med Phys ,2003,30 : 1125-1133. 被引量:1

二级参考文献18

  • 1.调强适形放射治疗[A].胡逸民.肿瘤放射物理学[C].北京:原子能出版社,1999.538-612. 被引量:23
  • 2Hanley J,Debois MM,Mah D,et al.Deep inspiration breath-hold technique for lung tumors:the potential value of target immobilization and reduced lung density in dose escalation.Int J Radiat Oncol Biol Phys,1999,45:603-611. 被引量:1
  • 3Ramsey CR,Scaperoth D,Arwcod D,et al.Clinical efficacy of respiratory gated conformal radiation therapy.Med Dosim,1999,24:115-119. 被引量:1
  • 4Shirato H,Shimizu S,Kitamura K,et al.Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor.Int J Radiat Oncol Biol Phys,2000,48:435-442. 被引量:1
  • 5Keall PJ,Chen GTY,Joshi S,et al.Time-the fourth dimension in radiotherapy (ASTRO panel discussion).Int J Radiat Oncol Biol Phys,2003,57:S8-S9. 被引量:1
  • 6Yu CX,Jaffray DA,Wong JW.The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation.Phys Med Biol,1998,43:91-104. 被引量:1
  • 7de Neve W,Heuvel F,De Beukeleer M,et al.Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch.Radiother Oncol,1992,24:45-54. 被引量:1
  • 8Hu YM,DM JR,Hu B.The precision and accuracy analysis of target position in X-ray stereotactic radiotherapy for extracranial lesions.In:Internation symposium of stereotactic radiosurgery (SRS/SRT).Taejon:Chungnam National University Hospital,1997. 被引量:1
  • 9Yan D,Vicini F,Wong J,et al.Adaptive radiation therapy.Phys Med Biol,1997,42:4123-4132. 被引量:1
  • 10Birkner M,Yan D,Alber M,et al.Adapting inverse planning to patient and organ geometrical variation algorithm and implementation.Med Phys,2003,30:2822-2831. 被引量:1

共引文献183

同被引文献31

  • 1Stine Korreman,科恩罗序,海伦捷.等.欧洲放射治疗及肿瘤协会和欧洲放疗研究所关于基于三维CT的影像引导系统报告:一种实用的技术回顾和指南[J].放疗和肿瘤,2010,94(2):129-144. 被引量:1
  • 2W.H.格林.S.Chelikani, K. Purushothaman, 等.约束非刚性配准在图像引导的自适应放疗中的使用[J].医学图像分析,2009,13(50):809-817. 被引量:1
  • 3O.FLUCK,C.维特尔,W.Wein,等.图形硬件上医学图像配准的调查[J].生物医学计算机方法和程序,2010. 被引量:1
  • 4丹尼尔 Rui-jters,哈尔 Romeny,保罗 Suetens.应用于内手术的GPU加速三维图像弹性配准[J].生物医学计算机方法和程序,2010. 被引量:1
  • 5罗布 H.爱尔兰.卡伦 E Dyker,大卫 CBarber,等.头颈部癌症放射治疗计划中PET/CT的非刚性图像配准[J].国际放射肿瘤生物物理杂志,2007,68(3):952-957. 被引量:1
  • 6彼得 J.Slomka,理查德 P 鲍姆.多模态图像配准软件:最先进的技术[J].欧州核医学分子影像杂志,2009,36(增刊):S44-S55. 被引量:1
  • 7He 王,苏尼尔 克里希南,王晓春,等.使用变形图像配准改善肝癌患者四维CT图像的软组织对比度[J].国际放射肿瘤生物物理杂志,2008,72(1):201-209. 被引量:1
  • 8Chang,J,Suh,TS,Jung,WG等.前列腺粒子定位中用EPID投影和变形配准减少金属伪影[J].韩国物理协会杂志,2009,54(6). 被引量:1
  • 9Iris E.范达姆,约翰 R 范 Stirnsende Koste,杰拉德 G 汉娜,等.Ⅰ期NSCLC中用变形配准提高4维CT扫描的靶区定义[J].放疗和肿瘤,2010,96(1):67-72. 被引量:1
  • 10M.Hub,M.L.凯斯勒,C.P.karger,B样条配准与模型算法-基于人工肺的准确性和可逆性的定量比较[A].IFMBE论文集[C].2009,25:790-792. 被引量:1

引证文献1

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部