摘要
介绍了漳泽电厂苏制给水泵的结构特点,针对运行中出现的振动现象进行了诊断分析。
The Structural properties of make - up pump made in the S. U. are introduced. The diagnostic analysis of the operational vibration of the make - up pump is made and the Eliminating measure of the pump vibrations are put forwar.
出处
《电力学报》
1998年第2期130-133,共4页
Journal of Electric Power
关键词
给水泵
振动
锅炉
发电厂
the make-up pump
vibration
diagnosis